Electrical Safety Topics

Electrical Safety Foundation International http://www.esfi.org/esfilib/isub.php?l0=esfilib&l1=index

Arc Fault Circuit Interrupter (AFCI) Explained: http://www.cpsc.gov/cpscpub/pubs/afcifac8.pdf   

http://www.mikeholt.com/mojonewsarchive/AFCI-HTML/HTML/AFCI_-_Update~20021209.htm

Ground Fault Circuit Interrupter (GFCI) information and required installation locations: http://www.ecmweb.com/mag/electric_code_basics_3/

ALUMINUM WIRING 

ALUMINUM WIRING HAZARDS

AMPS VOLTS DETERMINATION

CIRCUIT BREAKER FAILURE 

ELECTRICAL INSPECTION SAFETY 

ELECTRIC PANEL INSPECTION


ELECTRIC PANEL RUST 

FEDERAL PACIFIC FPE HAZARDS 

LIGHTNING PROTECTION 

MULTI-WIRE CIRCUITS 

ZINSCO / SYLVANIA HAZARDS

Why GFCI's Fail
(Taken from Occupational Health and Safety Magazine, November 2000
Reprinted with permission © 2000, Stevens Publishing Corporation)


Joseph E. Layton
Stevens Publishing Corp.


Electricity has been around since the beginning of time in the forms of lightning and static electricity. In 600 BC in Greece, it was observed that amber rubbed with wool would attract light objects such as straw, feathers, and bits of wood. Around 1570, William Gilbert, the man who is credited with coining the word “electricity,” discovered electrical properties in items other than amber. The electric light bulb was invented in 1802, and Thomas Edison was the first person to successfully market an incandescent lamp, in 1879.

With the ever-expanding use of electricity, the need was recognized for a national standard to regulate electrical installations nationwide. The National Electrical Code came into being in 1897. Through the National Fire Protection Association it became NFPA 70 and remains the same today. It is the electrical standard for the United States and other foreign countries, including Mexico. The code is not a training manual; rather, it is a uniform standard used by inspection agencies, designers, insurance companies, and others who are responsible for electrical installations. The code is a minimum requirement for safe installations, and parts of the code became Subpart S and Subpart K of OSHA’s standards.

GROUNDING
When electricity became part of our lives, whether in the workplace or at home, effective grounding became our means of protection. Grounding is still a required method of protection from shock in the event of an electrical fault. This is the separate wire that is run with the circuit conductors and connected to the non-current-carrying metal parts of equipment that could become energized because of a fault.

A grounding conductor is also required in cords that are connected to tools, equipment, and appliances. The only exception is if the tool is supplied through an isolation transformer with an ungrounded secondary of not over 50 volts or uses a system of approved double insulation. The grounding conductor gives a direct path back to the grounding electrode (ground rod, structural steel, etc.) if a fault occurs.

When the transistor was invented, we entered into a new era. Now, we were faced with items such as transistor radios, which operated on batteries or regular household current. In the mid to late 1960s, one could hardly read a newspaper or watch the evening news without reading or hearing about a kid or kids being electrocuted. Typically they would be sitting in the bathtub when their radio (plugged into household current) fell into the tub, and electrocuting them.

Hairstyles were changing during this period, and the hand-held hair dryer became a part of practically every household. They posed a problem because they were primarily used in the bathroom, near the lavatory. This presented additional hazards because the water piping system was grounded, and a fault in the hair dryer along with someone coming in
contact with the faucets could result in serious electrical shock or electrocution.

These factors led to introduction of Ground Fault Circuit Interrupters (GFCIs).

UNDERSTANDING GFCIs
One of the items covered in the National Electrical Code is Ground Fault Circuit Interrupters, or GFCIs. The GFCI is probably the most significant life-saving device ever invented for protection against serious injury or death caused by an electrical shock.

The GFCI is designed for “personal” protection, not for protection of equipment or the conductors of a circuit. While grounding is required and is a vital part of the safety of both people and equipment, the grounding conductor has nothing to do with the operation of GFCIs.

The GFCI senses an imbalance of current between the “hot” and “neutral conductor.” The GFCI really does not care about the current draw (amps) passing through, as long as it is within the designed limits of the device. Rather, it is monitoring the current difference in milliamperes between the hot and neutral. A milliamp is .001 or 1/1000 th of an ampere. If this difference is at 5 milliamperes, plus or minus 1 milliampere, the device “trips out,” breaking the circuit.

A handheld hair dryer that is rated at 1,400 watts, 120 volts, will have a current draw of approximately 11.6 amperes, or 11,600 milliamperes. An industrial 3/8-inch electric drill will have a current draw of between 4 and 6 amperes, or 4,000 to 6,000 milliamps.

While electricity performs many tasks for us and makes our lives more enjoyable, it is basically lazy. The lazy part is that it will seek the path of least resistance to a grounding source. The resistance in a copper wire used as the grounding conductor is very low and will allow current to flow rather freely. In the event of an electrical fault in equipment that has a grounding conductor, the current will flow to ground on the conductor.

EFFECTS OF ELECTRICITY
The adult body has about 500 Ohms of resistance. If a person’s body were to become the path to ground, the body would become a high impedance ground path. There is not enough current flowing through the body to trip an overcurrent device (a fuse or circuit breaker; the GFCI is not an overcurrent device.)

In order for an overcurrent device to trip, the current draw (amps) must exceed the rating of the device. For example, a circuit breaker rated at 20 amperes will not trip open until the current exceeds the 20 amperes. Using Ohm’s Law, on a 120 volt circuit with 500 Ohms of resistance, the current level would be 240 milliamperes, or about 1/4 th of an ampere. Even though this seems like a small about of current, it is quite deadly when passing through the body.

Shock in the range of 6 to 30 milliamps can be very painful, and the person in contact cannot let go of the circuit. At around 50 milliamps respiratory arrest is possible, with severe muscular contractions. Ventricular fibrillation starts around 67 milliamperes of current. This is when the heart basically starts fluttering and is not pumping blood through the system. If not stabilized, death is a real possibility.

So you can see that if the GFCI is functioning properly, the current level will never reach the danger point—because it trips at 5 milliamperes.

TESTING GFCIs
UL 1943 is the standard for testing GFCIs. Each manufacturer must ensure that its product meets this standard. Included in the listing and labeling for GFCIs are instructions that they be tested monthly.

Both the National Electrical Code and OSHA’s electrical standards require that equipment shall be used and installed in accordance with any instruction included in the listing and labeling. The purpose of this is to ensure as much as possible that the device is functioning properly.

The test is a very simple procedure where one can press the test button on the device to ensure that it does trip, breaking the circuit. This test button creates a difference of 5 milliamperes between the hot and neutral through a resister built in the device. There are GFCI testers in the marketplace where you can test the polarity of a receptacle and also trip the GFCI. I have stated that the grounding conductor has no part to play in the operation of the GFCI, but using the external tester the grounding conductor must be present because the tester is using the hot and grounding conductor to trip the device.

ARE YOUR GFCIs WORKING?
We take for granted that our GFCIs are providing protection if we can operate a tool, hair dryer, or other item through them. Yet this is not always the case. While the device will allow current to flow through it, the monitoring of the current may not be taking place.

Built into the device is a metal oxide varistor (MOV) used as a surge suppressor. The MOV absorbs the voltage surge and converts it into heat. Repeated surges can degrade the MOV, still allowing current to flow but not providing the protection required. Voltage surges such as lightning strikes in the area can cause a surge, as can utility company switching. In the event a GFCI trips out, is reset, and power is restored, you should go a step further and press the test button to insure that the device trips open to stop the current flow. If the device will not trip open, or if it trips and current continues to flow, the device is defective and must be replaced.

Some parts of the country are more susceptible to lightning strikes than others. This is a primary cause of GFCI failures. The International Association of Electrical Inspectors obtained information from the American Society of Home Inspectors about its findings in inspecting residences. This survey only covered parts of the United States, and some of the figures are staggering about the number of GFCIs that do not operate properly.

In parts of Florida, up to 58 percent of the GFCI circuit breakers were defective, and 33 percent of the receptacles. Of the states from which information was obtained, Washington state had the least number of failures. The survey covered parts of New York, Florida, Texas, California, Washington, and Illinois. IAEI, ASHI, and the National Electrical Manufacturing Association are joining forces get data from each state to give a true picture of the failures throughout the United States.

THE BOTTOM LINE FOR SAFETY
If you follow just these two steps, whether at home or at work, you can help ensure that your GFCIs function as life-protecting devices.

  1. Test them monthly as required.
  2. When a GFCI trips, reset and then trip it using either a GFCI tester or test buttons on the device. (Make sure this stops the current flow). Reset and use the circuit!

Joseph E. Layton (JLayton443@aol.com) is president of Layton’s Electrical Consulting Inc., located in King, N.C. He is a member of the American Society of Safety Engineers, the International Association of Electrical Inspectors, and the National Fire Protection Association.


GFCI 2005 NEC (National Electric code)

210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.

FPN: See 215.9 for ground-fault circuit-interrupter protection for personnel on feeders.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(1) Bathrooms
(2) Garages, and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use
Exception No. 1 to (2): Receptacles that are not readily accessible.
Exception No. 2 to (2): A single receptacle or a duplex receptacle for two appliances located within dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-and-plug connected in accordance with 400.7(A)(6), (A)(7), or (A)(8).
Receptacles installed under the exceptions to 210.8(A)(2) shall not be considered as meeting the requirements of 210.52(G)
(3) Outdoors
Exception to (3): Receptacles that are not readily accessible and are supplied by a dedicated branch circuit for electric snow-melting or deicing equipment shall be permitted to be installed in accordance with 426.28.
Receptacles installed under the exceptions to 210.8(A)(5) shall not be considered as meeting the requirements of 210.52(G).
(4) Crawl spaces — at or below grade level
(5) Unfinished basements — for purposes of this section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms and limited to storage areas, work areas, and the like
Exception No. 1 to (5): Receptacles that are not readily accessible.
Exception No. 2 to (5): A single receptacle or a duplex receptacle for two appliances located within dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-and-plug connected in accordance with 400.7(A)(6), (A)(7), or (A)(8).
Exception No. 3 to (5): A receptacle supplying only a permanently installed fire alarm or burglar alarm system shall not be required to have ground-fault circuit-interrupter protection.
(6) Kitchens — where the receptacles are installed to serve the countertop surfaces
(7) Laundry, utility, and wet bar sinks — where the receptacles are installed within 1.8 m (6 ft) of the outside edge of the sink
(8) Boathouses
(B) Other Than Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (5) shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Commercial and institutional kitchens — for the purposes of this section, a kitchen is an area with a sink and permanent facilities for food preparation and cooking
(3) Rooftops
(4) Outdoors in public spaces—for the purpose of this section a public space is defined as any space that is for use by, or is accessible to, the public

Exception to (3) and (4): Receptacles that are not readily accessible and are supplied from a dedicated branch circuit for electric snow-melting or deicing equipment shall be permitted to be installed in accordance with the applicable provisions of Article 426.
(5) Outdoors, where installed to comply with 210.63
(C) Boat Hoists. Ground-fault circuit-interrupter protection for personnel shall be provided for outlets that supply boat hoists installed in dwelling unit locations and supplied by 125-volt, 15- and 20-ampere branch circuits.


Aluminum wiring article: http://www.iaei.org/subscriber/magazine/06_a/hunter.html


 


ADAIR INSPECTION TREC#4563 1733 Goliad Dr Garland, TX 75042-4238
Phone: (972) 487-5634 Cell: (214) 328-8331

Radon Information | Staff & Associates | Testimonials | Contact Us | Lead in the home | Inspection Prices | Vendor List | My Favorite Links | RepairCostLifeExpectancyAge | Free Home Care Guide | Satisfaction Survey | Tech Tips | Affiliate Links | Fire Prevention & Safety | Ed. & Cetification | Sample Reports | Pool-Spa Safety | Electrical Safety | Environmental Research | EIFS - Stucco - Siding | Service Area | Phase Inspection | CRAP Photos | Infrared Thermography | I'm Licensed & Qualified! | Carbon Monoxide CO | Client Login | Home Buyer Checklist | Tell a Friend | Environmental Issues | Real Estate News | FAQ | Press Release | Glossary of Terms | Home | Our Service Area | Most Common Defects | Services | Inspection vs. Appraisal | Inspector vs. Engineer | New Home Inspection | Pre-purchase Inspection | Septic Inspection | What's an Inspection SOP | Listing Inspection | Order Inspections | Winterize your Home | Mold in the home | ReportReadingGlossary | How to prepare | Residential investment | NACHI Membership | NACHI Code of Ethics | How to Hire an Inspector | HVAC Issues | Roofing Issues | Hidden Water Damage | Plumbing Issues | Termites and Other Pests | Asbestos Information

Copyright © 2007 ADAIR INSPECTION TREC#4563
Portions Copyright © 2007 a la mode, inc.
Another XSite by a la mode, inc. | Admin LoginTerms of UseSite Map