Some of these photos are so ridiculous they appear funny but all are avoidable and could or would cost the owners their property or lives if not addressed and repaired immediately.

I offer Buyer, Seller, Owner, Investment, and Warranty Inspections

Think about your investment Aren't you worth it? All of these photos passed the City Inspections and were given Certificates of Occupancy

CRAP is the acronym for: Can’t Really Apply Properly                                               a.k.a. I-CRAP the tradesperson is speaking of his/herself “I Can’t Really Apply Properly” a.k.a. I-CRAPED as in “I Can’t Really Apply Properly Every Day.” Just showing up for the check attitude.

This term has been around as long as man has constructed. Used often on jobsites when mistakes are made, things don’t go together as designed, mismanagement, and when workers are not properly trained or don’t take pride in their job.

Below are photos of CRAP other inspectors and I have found from around the world. CRAP is not a local thing this epidemic is worldwide. This is why every home needs a Professional Inspection and why I enjoy my job. “They build them and I find them”

 

Is this what they mean by "NO FAULT DIVORCE"? Poisonous combusted fuel gases are being discharged directly into the attic space where the HVAC equipment is located.

The plumber never installed the drain line, also notice the drip. Photo by badair

20-30 of these were growing in the crawlspace and attic. Photo by badair

Pendant light fixture over bath tub is a BAD IDEA. Photo by badair

Is it just me or isn't it a BAD IDEA to have an electric switch inside the tub-shower area? But I see this a lot

 

Panel wiring was cooking, just a matter of time before property loss or loss of life occurs

 

HVAC return air at bathroom, and they wonder where that odor comes from?

Plumber cut oversized hole in floor and cut out floor joist. This is after the Framing Green Tag had been issued. That is a bath tub above+Water+Body=Disaster waiting to happen. Photo by badair

HVAC return air at laundry area with gas fired dryer this can create negative pressure that could extinguish flame or distribute Carbon Monoxide and other poisonous combusted fuel gases

 

Dryer flue vent in HVAC return air compartment (See above)

 

Commode drain is not properly supported. Photo by badair

 

Ingenious idea to protect the wood floors. I'll sell you a pair!

 

Water heaters in garages must be elevated and protected from impact. Photo by badair

 

Atypical rafter splice this was one of eight

 

The pet door breeches the required separation barrier between the living space and the garage. Photo by badair

 

Service stop valve is against cabinet wall and will never terminate water supply in an emergency or when the fixture require repair or replacement. Photo by badair

 

Dryer vent embedded in brick, now where do you think the heat and moisture is going? Photo by badair

 

Shower fixture and bulb were not approved for wet location installation. Photo by badair

 

All of this insulation was installed backwards. Photo by badair

Do you see the female black widow spider and her egg sac at a water meter? BE CAREFUL! I run into these, other critters, and Brown Recluse on a number of inspections. Photo by badair

 

This 8 year old fireplace flue was never properly connected, allowing poisonous flue gases to escape and circulate throughout the home. Photo by badair

 

Bleeding GFCI outlets all were defective at this inspection. Photo by badair

 

Hundreds have been written up notice the wiring is made up inside and outside this junction box, some folks don't even bother with the J-box or wire nuts, tape and open junctions work for them. Photo by badair

 

Another plumber hard at it, why couldn't they add a few fittings? Missed 2 floor joists then cuts the main girder in half. Photo by badair

 

Guess what? Yep, you're right, the dishwasher does leak. I find at least 20 like these a year if not more at DW, hydro-tubs, shower pans or sinks. Photo by badair

 

This microbial outbreak is but one example of what happens when attics are not properly ventilated. Smelled funky!

Every rafter in this hose was cut and installed incorrectly!

 

HVAC malfunction this is a unit icing up as it's getting ready for meltdown. Photo courtesy of Rick Hurst Home Works Inspection Co.

 

Does yours look like this? This one is asbestos. Photo by badair

 

Chimney or entire house fire, when??? 

Meth or coke found behind hidden panel, BUSTED!

Why coverplates are absolutely necessary

The day this happens my business gets sold, this site is shut down, and I'll see you in Belize!

This is what an August attic feels like to Texas Inspectors

A nurse was selling this house and thought this would divert the inspectors attention, not funny and things didn't go as planned. The ductwork in the background had split in two dumping most of the conditioned air into the attic not the living space.

A few code diagrams (Under Construction)

2003_IRC_Commentary_stairway_description_01.jpg Stair tolerance

200452751016_016NEC_BONDING.jpg Pool bonding and grounding items and locations

AFCI.gif AFCI area and items controlled

danger-window1.jpg Tempered glass and fall protection

elec-bathrm-8.jpg Specific type of fixture locations or off limit bathroom areas

Purlins.jpg Installation guide

R211.5.4-Landing.jpg Landing tolerance

R311.4.3thresholdheight.jpg Threshold tolerance

Dedicated to the wives of home inspectors!


ADAIR INSPECTION TREC#4563 1733 Goliad Dr Garland, TX 75042-4238
Phone: (972) 487-5634 Cell: (214) 328-8331

Radon Information | Staff & Associates | Testimonials | Contact Us | Lead in the home | Inspection Prices | Vendor List | My Favorite Links | RepairCostLifeExpectancyAge | Free Home Care Guide | Satisfaction Survey | Tech Tips | Affiliate Links | Fire Prevention & Safety | Ed. & Cetification | Sample Reports | Pool-Spa Safety | Electrical Safety | Environmental Research | EIFS - Stucco - Siding | Service Area | Phase Inspection | CRAP Photos | Infrared Thermography | I'm Licensed & Qualified! | Carbon Monoxide CO | Client Login | Home Buyer Checklist | Tell a Friend | Environmental Issues | Real Estate News | FAQ | Press Release | Glossary of Terms | Home | Our Service Area | Most Common Defects | Services | Inspection vs. Appraisal | Inspector vs. Engineer | New Home Inspection | Pre-purchase Inspection | Septic Inspection | What's an Inspection SOP | Listing Inspection | Order Inspections | Winterize your Home | Mold in the home | ReportReadingGlossary | How to prepare | Residential investment | NACHI Membership | NACHI Code of Ethics | How to Hire an Inspector | HVAC Issues | Roofing Issues | Hidden Water Damage | Plumbing Issues | Termites and Other Pests | Asbestos Information

Copyright © 2007 ADAIR INSPECTION TREC#4563
Portions Copyright © 2007 a la mode, inc.
Another XSite by a la mode, inc. | Admin LoginTerms of UseSite Map