Standards of Practice

All of my Inspections are an unbiased, professional assessment of over 100 items that provides you with an expert opinion in report form on the condition of the physical structure and it's various systems. As a Professionally Licensed Real Estate Inspector, it is my job to address your concerns about any defective systems that could become costly surprises. I will gladly discuss remedies and repair recommendations for each specific situation.

In order to prepare the report, the inspector must conduct a visual and systems operation inspection of the property and components contained within. The inspection process typically takes at least 3 or more hours to complete. This of course will vary according to the size, condition, and age of the property. I strongly encourage you to accompany me during the inspection. This will give you a chance to ask questions and become familiar with the systems.

When your inspection is complete. You will receive a thorough written report accompanied by digital photographs. I will also discuss any routine maintenance tasks that are required to keep the home and its systems in top condition, as well as answer any questions you may have.

All of my Inspections are in compliance with the Texas Real Estate Commission (TREC) Standards of Practice. The Standards of Practice are the minimum levels of inspection practice required of inspectors for the accessible parts, components, and systems typically found in improvements to real property, excluding detached structures, decks, docks and fences. The inspector may provide a higher level of inspection performance than required by the standards of practice and may inspect parts, components, including detached structures, decks, docks, fences, and other systems in addition to those described by the standards of practice.

(Please see the complete Texas Administrative Code and Standards of Practice below)

Based on what is Present, Visible, and Accessible the Inspector will inspect the following items that may be included in your thorough inspection report:

  • (AFCI) ARC FAULT CIRCUIT INTERRUPTOR TESTING

  • AIR CONDITIONING, HEATING EQUIPMENT, VENTS, AND DUCTWORK 

  • ALARM SYSTEMS, SMOKE, FIRE, AND CARBON MONOXIDE DETECTION

  • ATTIC, STAIRS, INSULATION, VENTS, AND ASSOCIATED STRUCTURE SYSTEMS

  • BATHROOM FIXTURES, EXHAUST VENTS, AND HEATERS

  • CABINETS, COUNTER TOPS, AND CLOSETS

  • CRAWLSPACE, PIERS, BEAMS, GIRDERS, VENTS, AND SUBFLOOR STRUCTURES

  • DISHWASHER

  • DOOR BELL OR CHIME

  • EIFS: EXTERIOR INSULATED FINISH SYSTEMS 

  • ELECTRICAL SERVICE ENTRANCE, PANELS, AND BRANCH CIRCUITS

  • EXTERIOR WALLS, DOORS, SEALANTS, AND WEATHER STRIPPING

  • FIREPLACE, HEARTH, DAMPER, FLUE, CAP, AND ARRESTORS

  • FOOD WASTE DISPOSAL

  • FOUNDATION

  • FLOOR COVERINGS

  • GARAGE DOOR(S) AND OPENER(S) 

  • GAS LEAK DETECTION (TIF 8800) not matches or soap bubbles

  • GAS SUPPLY SYSTEM FROM METER TO APPLIANCES

  • (GFCI) GROUND FAULT CIRCUIT INTERRUPTOR TESTING

  • GRADING, DRAINAGE, GUTTER, AND DOWNSPOUTS

  • HYDROTHERAPY TUB & EQUIPMENT   

  • INTERIOR WALLS, DOORS, CEILINGS, AND FLOORS

  • LANDSCAPING EFFECTS ON STRUCTURE

  • LAWN AND GARDEN SPRINKLER SYSTEMS

  • MICROWAVE

  • OVEN, COOKTOP, AND RANGE

  • OTHER INSTALLED KITCHEN APPLIANCES

  • OUTDOOR COOKING EQUIPMENT

  • PLUMBING SUPPLY, DRAINS, WASTE, AND VENTS

  • PORCHES, DECKS, BALCONIES, STAIRS, AND HANDRAILS

  • RANGE HOOD AND EXHAUST VENT 

  • ROOF COVERING, FLASHINGS, AND ROOF STRUCTURE

  • SEPTIC SYSTEMS

  • STORAGE BUILDINGS WITH UTILITIES

  • SWIMMING POOL, HOT TUB, SECURITY, AND ASSOCIATED EQUIPMENT 

  • TRASH COMPACTOR

  • WATER HEATER 

  • WELLS

  • WINDOWS, SCREENS, LINTELS, FLASHING, AND DOOR GLAZING

  • WHOLE HOUSE VACUUM SYSTEMS

  • WOOD DESTROYING INSECTS AND MICROBIAL ORGANISMS

  • Additional items and systems unique to a particular property can also be inspected

     

  •  

    Texas Administrative Code

     

     

    TITLE 22

    EXAMINING BOARDS

    PART 23

    TEXAS REAL ESTATE COMMISSION

    CHAPTER 535

    GENERAL PROVISIONS

    SUBCHAPTER R

    REAL ESTATE INSPECTORS

    RULE §535.227

    Standards of Practice: General Provisions

     


    (a) Definition of terms. The following words have the following meanings, unless the context clearly indicates otherwise.

      (1) Chapter 1102--Texas Occupations Code, Chapter 1102.

      (2) Functioning--Performing in an expected or required manner; carrying out the design purpose or intended operation of a part, system, component, member.

      (3) Inaccessible--Not having access without the use of special tools, equipment, or instruments, or removing doors, walls, stored items or similar obstructions, or by causing damage to a structure, finish or component, equipment or system, or by virtue of inadequate clearance, walkways, passageways, or hazardous condition.

      (4) In Need of Repair--Does not adequately function or perform.

      (5) Inspect--To look at and examine accessible items, parts, systems or components without, except as required by the rules of the Texas Real Estate Commission, laboratory, scientific or engineering evaluation or testing, destructive tests or the dismantling or removal of parts, members or components.

      (6) Inspector--A person licensed as a professional inspector, a person licensed as an apprentice inspector or a person licensed as a real estate inspector.

      (7) Performance--The act of carrying out, completing, executing or achievement of an operation, design or function in a manner consistent with the intent of the manufacturer, designer or accepted industry practice.

      (8) Report--A written or oral communication of the inspector's opinions, observations, determinations, and findings in an inspection.

      (9) Standards of Practice--§535.227 of this title (relating to Standards of Practice: General Provisions), §535.228 of this title (relating to Standards of Practice: Inspection Guidelines for Structural Systems, §535.229 of this title (relating to Standards of Practice: Inspection Guidelines for Mechanical Systems: Appliances, Cooling Systems, Heating Systems, Ducts, Vents and Flues, and Plumbing Systems), §535.230 of this title (relating to Standards of Practice: Inspection Guidelines for Electrical Systems) and §535.231 of this title (relating to Standards of Practice: Optional Systems).

    (b) Scope.

      (1) The standards of practice are the minimum levels of inspection practice required of inspectors for the accessible parts, components, and systems typically found in improvements to real property, excluding detached structures, decks, docks and fences. The inspector may provide a higher level of inspection performance than required by the standards of practice and may inspect parts, components, and systems in addition to those described by the standards of practice.

      (2) The inspector shall:

        (A) inspect items, parts, systems, components and conditions which are present and visible at the time of the inspection, but the inspector is not required to determine or estimate the remaining life expectancy or future performance of any inspected item, part, system or component;

        (B) operate mechanical and electrical equipment, systems, and appliances during an inspection in normal modes and operating range at the time of the inspection;

        (C) report which of the parts, components, and systems present in the property have or have not been inspected;

        (D) report as in need of repair inspected parts, components or systems that are not functioning or that the standards of practice require the inspector to report as in need of repair;

        (E) address all of the parts, components, and systems contained in the standards of practice in the property being inspected.

        (F) complete the standard inspection report form under §535.223 of this title (relating to Standard Inspection Reports) if that section applies;

        (G) identify in any written report the inspector who performed the inspection by name and license number;

        (H) comply with any other law or license requirement necessary to perform inspections or services other than what is required by the standards of practice, such as an air-conditioning and refrigeration contractor license which may be required for the inspector to make a direct in-line connection to a refrigerant system, or a structural pest control license which may be required to perform a wood-destroying-insect inspection;

      (3) In the event of a conflict between a specific provision and a general provision in the standards of practice, the specific provision controls. The standards of practice do not apply to the following:

        (A) parts, components or systems other than those specifically described;

        (B) conditions other than those specifically described, such as environmental conditions, presence of toxic or hazardous wastes or substances, presence of termites or other wood-destroying insects or organisms, compliance with codes, ordinances, statutes or restrictions or the efficiency, quality, durability of any item inspected;

        (C) any part, component or system the inspector excludes under the departure provision in this section; and

        (D) any determination of insurability or warrantability of any part, component or system.

    (c) Departure Provision.

      (1) An inspector shall exclude from the inspection any part, component or system which the inspector is not competent or qualified to inspect.

      (2) An inspector may exclude any part, component or system required for inspection by the standards of practice which is inaccessible, cannot be inspected due to circumstances beyond the control of the inspector, or the inspector's client has agreed is not to be inspected.

      (3) This departure provision does not prohibit an inspector from specializing nor require the inspector to specifically exclude other parts, components or systems not ordinarily considered a part of the inspector's specialty. However, the inspector shall comply with the standards of practice for the items being inspected.

      (4) If an inspector excludes any part, component or system listed in the standards of practice, other than one which the client has agreed is not to be inspected, the inspector shall:

        (A) advise the client at the earliest practicable time that the specific part, component or system will not be included in the inspection; and

        (B) state in any written inspection report that the excluded part, component or system was not inspected.

    (d) Enforcement. Failure to comply with §535.227 of this title (relating to Standards of Practice: General Provisions), §535.228 of this title (relating to Standards of Practice: Inspection Guidelines for Structural Systems, §535.229 of this title (relating to Standards of Practice: Inspection Guidelines for Mechanical Systems: Appliances, Cooling Systems, Heating Systems, Ducts, Vents and Flues, and Plumbing Systems), §535.230 of this title (relating to Standards of Practice: Inspection Guidelines for Electrical Systems) and §535.231 of this title (relating to Standards of Practice: Optional Systems) is a ground for disciplinary action as prescribed by Chapter 1102 and §535.224 of this title (relating to Proceedings before the Committee).

     

     

     

     

     

    RULE §535.228

     

     

     

     

    Standards of Practice: Inspection Guidelines for Structural Systems

     

    (a) Foundations. The inspector shall:

      (1) report the type of foundation (for example, slab-on-grade or pier and beam);

      (2) inspect the foundation, related structural components and/or slab surfaces;

      (3) inspect the crawl space area to determine the general condition of foundation components and report the method used to observe the crawl space if the inspector did not enter the crawl space because the space was inaccessible, hazardous conditions were present, or access or visibility was limited;

      (4) render a written opinion as to the performance of the foundation;

      (5) report general indications of foundation movement that are present and visible, such as sheetrock cracks, brick cracks, out-of-square door frames or floor slopes;

      (6) report as in need of repair any post tensioned cable ends that are not protected;

      (7) report as in need of repair a crawl space that does not appear to be adequately ventilated;

      (8) report as in need of repair conditions or symptoms that may indicate the possibility of water penetration that are present and visible, such as improper grading around foundation walls or plumbing leaks; and

      (9) report as in need of repair conditions that are present and visible and may be adversely affecting foundation performance, such as erosion or water ponding.

    (b) Specific limitations for foundations. The inspector is not required to enter a crawl space or any areas where headroom is less than 18 inches and the width of the access opening is less than two feet, or where the inspector reasonably determines conditions or materials are hazardous to health or safety of the inspector.

    (c) Interior walls, doors, ceilings and floors. The inspector shall:

      (1) report as in need of repair deficiencies of the surfaces of walls, ceilings and floors as related to structural performance or water penetration that are present and visible;

      (2) report as in need of repair accessible doors that do not operate properly, excluding locks and latches;

      (3) report as in need of repair deficiencies in steps, stairways, balconies and railings,

      (4) report as in need of repair spacings between intermediate balusters, spindles, or rails for steps, stairways, balconies, and railings that permit passage of an object greater than four inches in diameter; and

      (5) report as in need of repair the absence of safety glass in hazardous locations.

    (d) Specific limitations for Interior walls, doors, ceilings and floors. The inspector is not required to do the following:

      (1) determine the condition of floor, wall or ceiling coverings unless such conditions affect structural performance or indicate water penetration;

      (2) report obvious damage to floor, wall or ceiling coverings;

      (3) determine the condition of paints, stains and other surface coatings; or

      (4) determine condition of cabinets.

    (e) Exterior walls and doors, windows and door glazing. The inspector shall:

      (1) report as in need of repair present and visible deficiencies of exterior walls that are related to structural performance and water penetration;

      (2) report as in need of repair deficiencies in the condition and operation of exterior doors and garage doors, including door locks and latches when present.

      (3) report as in need of repair damaged glazing in windows and exterior doors;

      (4) report as in need of repair any insulated windows that are obviously fogged or display other evidence of broken seals;

      (5) report as in need of repair the absence of safety glass in hazardous locations;

      (6) report as in need of repair missing or damaged window and door screens;

      (7) report as in need of repair in homes having burglar bars the absence of functional keyless burglar bars in appropriate locations;

      (8) report as in need of repair inoperable windows at burglar bar locations of sleeping rooms or egress areas and any inoperable windows at other randomly sampled accessible burglar bar locations; and

      (9) report as in need of repair spacings between intermediate balusters, spindles and rails that permit passage of an object greater than four inches in diameter.

    (f) Specific limitations for exterior walls and doors, windows and door glazing. The inspector is not required to do the following:

      (1) report the condition or presence of storm windows or doors, awnings, shutters or security devices or systems;

      (2) determine the condition of paints stains or other surface coatings; or

      (3) determine the presence of, or extent or type of, insulation or vapor barriers in exterior walls.

    (g) Fireplace and chimney. The inspector shall:

      (1) report as in need of repair deficiencies in the visible components and structure of the chimney and fireplace;

      (2) inspect the interior of the firebox and the visible flue area, and report as in need of repair built up creosote in visible areas of the firebox and flue (the inspector is not required to determine the adequacy of the draft or perform a chimney smoke test);

      (3) report as in need of repair a damper that does not operate;

      (4) report as in need of repair the presence of non-combustible hearth extension;

      (5) report as in need of repair deficiencies in the lintel, hearth and material surrounding the fireplace, including clearances from combustible materials;

      (6) report as in need of repair the absence of firestopping at the attic penetration of the chimney flue, where accessible;

      (7) report as in need of repair any gas log lighter valves that do not function or leak gas;

      (8) report as in need of repair any circulating fan that does not operate, if present;

      (9) report as in need of repair deficiencies in combustion air vent, if present; and

      (10) report as in need of repair deficiencies in chimney coping or crown, caps or spark arrestor (inspected from ground level at a minimum).

    (h) Roof, roof structure and attic. The inspector shall:

      (1) report the type of roof covering and report as in need of repair:

        (A) a roof covering that is not appropriate for the slope of the roof;

        (B) fasteners that are not present or that are not appropriate, (where it can be reasonably determined); and

        (C) roof jacks, flashing and counter flashing that are not present or not properly installed.

      (2) inspect the general condition of, and report evidence of previous repairs to, flashing, skylights and other roof penetrations;

      (3) report as in need of repair inadequate attic space ventilation;

      (4) report as in need of repair deficiencies in the roof covering, structure and sheathing;

      (5) report any visible evidence of moisture penetration;

      (6) report as in need of repair the lack of or inappropriate installation of components such as purlins, struts, collar ties or rafter ties, where necessary;

      (7) report as in need of repair excessive deflections or depressions in the roof's surface relating to the performance of the framing and the roof deck;

      (8) enter and inspect attic space(s) except when inadequate access or hazardous conditions exist as reasonably determined by the inspector and report the method used to inspect the attic if the inspector did not enter the attic;

      (9) report the method used to inspect the roof if the inspection is performed from other than roof level;

      (10) inspect for the presence, and report the approximate depth of, insulation where visible; and

      (11) report as in need of repair deficiencies in visible installed gutter and downspout systems.

    (i) Specific limitations for roof, roof structure and attic. The inspector is not required to do the following:

      (1) determine the remaining life expectancy of the roof covering; or

      (2) inspect the roof from the roof level if the inspector reasonably determines that the inspector cannot safely reach or stay on the roof, or that damage to the roof or roof covering may result from walking on the roof.

    (j) Porches and decks. The inspector shall:

      (1) report as in need of repair structural deficiencies in porches, decks, steps, balconies and carports as to visible footings, joists, deckings, railings and attachment points, where applicable; and

      (2) report as in need of repair (except for decks which are not higher than 30 inches as measured from the adjacent grade) spacings between intermediate balusters, spindles or rails that permit passage of an object greater than four inches in diameter.

    (k) Specific limitations for porches and decks. The inspector is not required to inspect detached structures or waterfront structures and equipment, such as docks or piers.

     

    RULE §535.229

    Standards of Practice: Inspection Guidelines for Mechanical Systems: Appliances, Cooling Systems, Heating Systems, Ducts, Vents and Flues, and Plumbing Systems

     

    (a) Dishwasher. The inspector shall:

      (1) report as in need of repair any deficiencies in the door gasket, control knobs and interior parts, including the dish tray, rollers, spray arms and the soap dispenser;

      (2) report as in need of repair any interior signs of rust;

      (3) report as in need of repair a door spring that does not operate properly;

      (4) report as in need of repair deficiencies in the discharge hose or piping or the lack of back flow prevention;

      (5) report as in need of repair units that are not securely mounted;

      (6) report as in need of repair any water leaks;

      (7) inspect the unit's operation in normal mode with the soap dispenser closed; and

      (8) report as in need of repair spray arms that do not turn, soap dispensers that do not open or drying elements that do not operate.

    (b) Food waste disposer. The inspector shall:

      (1) report as in need of repair any deficiencies in the splash guard, grinding components, wiring and exterior;

      (2) report as in need of repair a unit that is not securely mounted; and

      (3) inspect the operation of the unit and report as in need of repair any unusual noise or vibration level and any signs of water leaks.

    (c) Range exhaust vent. The inspector shall:

      (1) report as in need of repair any deficiencies in the filter, vent pipe, light and switches;

      (2) inspect the operation of the blower and report as in need of repair any unusual sounds or vibration levels, or if the blower does not operate at all speeds;

      (3) report as in need of repair a vent pipe that does not terminate outside the structure when the unit is not of recirculating type or configuration.

      (4) report as in need of repair a vent pipe that is of inadequate material; and

      (5) report as in need of repair the absence of a range exhaust vent.

    (d) Electric or gas ranges. The inspector shall:

      (1) report as in need of repair broken or missing knobs, elements, drip pans or other parts, inadequate clearance from combustible material, or the absence of an anti-tip device;

      (2) report as in need of repair signal lights and elements or burners that do not operate at low and high settings;

      (3) report as in need of repair improper materials that are used for the gas branch line and the connection to the appliance; and

      (4) report as in need of repair the absence of a gas shut-off valve, or valve that is not properly located, is inaccessible, or leaks.

    (e) Electric or gas ovens. The inspector shall:

      (1) report as in need of repair any broken or missing knobs, handles, glass panels, door hinges, lights or light covers or other parts, or inadequate clearance from combustible material;

      (2) report as in need of repair deficiencies in the door gasket, tightness of closure and operation of the latch;

      (3) report as in need of repair an oven that is not securely mounted;

      (4) report as in need of repair heating elements and thermostat sensing elements that are not properly supported;

      (5) report as in need of repair deficiencies in the operation of the heating elements or the lighting, operation and condition of the flame;

      (6) report as in need of repair deficiencies in the operation of the clock and timer, thermostat and door springs; and

      (7) report as in need of repair any inaccuracy of the thermostat more than a 25 degree range plus or minus of a 350 degree setting, as measured by a thermometer.

    (f) Microwave oven. The inspector shall:

      (1) report as in need of repair any broken or missing knobs, handles, glass panels, or other parts, or a unit that is not securely mounted;

      (2) report as in need of repair any deficiencies in the door and seal (the inspector is not required to test for radiation);

      (3) report as in need of repair an oven that does not operate by heating a container of water or with other test equipment, as reasonably determined by the inspector; and

      (4) report as in need of repair a light that does not operate.

    (g) Trash compactor. The inspector shall:

      (1) inspect the overall condition of the unit;

      (2) report as in need of repair a unit that does not operate or operates with unusual noise or vibration levels; and

      (3) report as in need of repair a unit that is not securely mounted in place.

    (h) Other built-in appliances. The inspector shall report as in need of repair any deficiencies in condition or operation of other built-in appliances not listed in this section.

    (i) Bathroom exhaust vents and electric heaters. The inspector shall operate the unit, and report as in need of repair unusual sounds, speed and vibration levels or, when possible, vent pipes that do not terminate outside the structure.

    (j) Whole house vacuum system. The inspector shall:

      (1) inspect the condition of the main unit;

      (2) report as in need of repair a unit that does not operate; and

      (3) inspect the system from all accessible outlets throughout the house.

    (k) Water heaters. The inspector shall:

      (1) report the energy source;

      (2) inspect the unit and report as in need of repair fittings that leak or are corroded;

      (3) report as in need of repair temperature and pressure relief valve piping that lacks gravity drainage, is improperly sized (no smaller than the outlet fittings), has deficiencies in material, or lacks a correct termination;

      (4) report as in need of repair a temperature and pressure relief valve that does not operate when the valve is of an operable type and operation will not cause damage to persons or property as reasonably determined by the inspector (for example, it would be reasonable not to operate the valve if there is improper or undetermined termination of the drain pipe, a corroded or damaged valve, improper installation of valve or drain pipe, the drain pipe is of inappropriate material or there is no water supply cut-off valve at the unit);

      (5) report as in need of repair any broken or missing parts, covers or controls;

      (6) report as in need of repair deficiencies in the burner, flame and burner compartment, the operation of heating elements and the condition of wiring;

      (7) report as in need of repair deficiencies in materials used for the gas branch line and the connection to the appliance, the absence of a gas shut-off valve, or a valve that is not properly located, is inaccessible, or leaks;

      (8) if applicable, report as in need of repair deficiencies in the vent pipe, draft diverter, draft hood and their condition, draft, proximity to combustibles and vent termination point, observing for adequate combustion and draft air;

      (9) report as in need of repair the lack of a safety pan and drain (including the termination of the drain line) when applicable;

      (10) report as in need of repair an unsafe location or installation; and

      (11) inspect garage units or units which are located in rooms or enclosures opening into a garage and report as in need of repair the following:

        (A) a lack of protection for physical damage to the unit; and

        (B) burners, burner ignition devices or heating elements, switches or thermostats that are not a minimum of 18 inches above the lowest garage floor elevation.

    (l) Doorbell and chimes. The inspector shall:

      (1) inspect the condition of the unit and report as in need of repair a unit that does not operate; and

      (2) report as in need of repair any deficiencies in visible and accessible parts.

    (m) Attic power vents. The inspector shall:

      (1) report as in need of repair deficiencies in the operation and installation of the unit, including the wiring and mounting of the thermostat control, if so equipped and accessible; and

      (2) report as in need of repair unusual sounds or speed and vibration levels.

    (n) Garage door operator. The inspector shall:

      (1) report as in need of repair deficiencies in the installation, condition and operation of the garage door operator;

      (2) operate the door both manually and by an installed automatic door control;

      (3) report as in need of repair a door that does not automatically reverse during closing cycle, any installed electronic sensors that are not operable or not installed at the proper heights above the garage floor; and

      (4) report as in need of repair door locks or side ropes that have not been removed or disabled.

    (o) Hydrotherapy or whirlpool equipment. The inspector shall:

      (1) report as in need of repair a unit that does not operate, leaks, or is inaccessible;

      (2) report as in need of repair a unit that lacks a ground fault circuit interrupter or has an interrupter that does not operate;

      (3) report as in need of repair switches that are not in a safe location or do not operate;

      (4) report evidence of leaks under the tub if the access cover is available and accessible, reporting when the cover is absent or inaccessible (the inspector is not required to determine the adequacy of self-draining features of the circulation system); and

      (5) report as in need of repair deficiencies in the ports, valves, grates and covers.

    (p) Specific limitations for appliances. The inspector is not required to do the following:

      (1) operate or determine the condition of other auxiliary components of inspected items; or

      (2) inspect self-cleaning functions.

    (q) Cooling systems other than evaporative coolers. The inspector shall:

      (1) report the type of system and energy sources;

      (2) operate the system using normal control devices except when the outdoor temperature is less than 60 degrees Fahrenheit;

      (3) inspect for proper performance; such as by observing the temperature difference between the supply air and the return air or noticeable vibration of the blower fan and report as in need of repair any deficiencies;

      (4) report as in need of repair the lack of, or deficiencies in drainage of, condensate drain line and secondary drain line when applicable, including pipes made of inadequate material;

      (5) report as in need of repair a primary drain pipe that terminates in a sewer vent, if the termination is visible;

      (6) report as in need of repair a safety pan that is not appropriately sized for the evaporator coil or free of water or debris;

      (7) report as in need of repair a return chase and plenum that are not free of improper and hazardous conditions, such as gas pipes, sewer vents, refrigerant piping or electrical wiring.

      (8) report as in need of repair the lack of insulation on refrigerant pipes and the primary condensate drain pipe;

      (9) report as in need of repair a condensing unit that does not have adequate clearances, or air circulation, or that has deficiencies in the condition of fins, location, levelness and elevation above ground surfaces; and

      (10) report as in need of repair conductor sizing and over-current protective devices that are not appropriately sized for the unit.

    (r) Evaporative coolers. The inspector shall:

      (1) operate the motor and report as one or two speed;

      (2) observe the electrical pigtail connection at the motor

      (3) inspect the power source in the unit;

      (4) report as in need of repair a pump that does not function or deficiencies in the spider tubes, tube clips and bleeder system;

      (5) report as in need of repair deficiencies in the water supply line and float bracket;

      (6) report as in need of repair the absence of a minimum one-inch air gap between water discharge at float and water level;

      (7) report as in need of repair deficiencies in the fan (blower) and squirrel cage or rust build-up, deterioration or corrosion;

      (8) report as in need of repair deficiencies in the fan belt and pulleys;

      (9) report as in need of repair deficiencies in the housing side panels, the water trays, the exterior housing and the roof frame;

      (10) report as in need of repair deficiencies in the roof jack or other mounting point and the location of the seasonal damper at the unit; and

      (11) report as in need of repair deficiencies in the interior registers and the supply duct.

    (s) Specific limitations for cooling systems. The inspector is not required to do the following:

      (1) inspect for the pressure of the system coolant or determine the presence of leaks;

      (2) program digital-type thermostats or controls; or

      (3) operate setback features on thermostats or controls.

    (t) Heating systems. The inspector shall:

      (1) report the type of heating system and its energy sources;

      (2) report as in need of repair a system that does not operate properly using normal control devices;

      (3) report as in need of repair deficiencies in the controls and accessible operating components of the system;

      (4) in gas units, inspect the burner, and report as in need of repair deficiencies in the burner compartment, type, condition, draft and termination of the vent pipe, or proximity to combustibles; the lack of combustion and draft air or inappropriate location, or the lack of forced air in the burner compartment (full evaluation of the integrity of a heat exchanger requires dismantling of the furnace and is beyond the scope of a visual inspection);

      (5) report as in need of repair gas units that display flame impingement, uplifting flame, improper flame color or excessive scale buildup;

      (6) report as in need of repair gas units that use improper materials for the gas branch line and the connection to the appliance;

      (7) report as in need of repair in gas units deficiencies in materials used for the gas branch line and the connection to the appliance, the absence of a gas shut-off valve, or a valve that is not properly located, is inaccessible, or leaks; and

      (8) report as in need of repair elements in electric furnaces that do not operate;

      (9) report as in need of repair a return chase or plenum that are not free of improper and hazardous conditions, such as gas pipes, sewer vents, refrigerant piping or electrical wiring; and

      (10) report if the inspector deemed the furnace to be inaccessible.

    (u) Specific limitations for heating systems. The inspector is not required to do the following:

      (1) inspect accessories such as humidifiers, air purifiers, motorized dampers, heat reclaimers, electronic air filters or wood-burning stoves;

      (2) determine the efficiency or adequacy of a system;

      (3) program digital-type thermostats or controls; or

      (4) operate radiant heaters, steam heat systems or unvented gas-fired heating appliances.

    (v) Ducts, vents (including dryer vents) and flues. The inspector shall:

      (1) report as in need of repair deficiencies such as damaged ducting or insulation, improper material or improper routing of ducts where visible and accessible;

      (2) report as in need of repair the absence of air flow at all accessible supply registers in the habitable areas of the structure;

      (3) report as in need of repair deficiencies in accessible duct fans and filters;

      (4) report as in need of repair deficiencies in installation, such as gas piping, sewer vents, electrical wiring or junction boxes in the plenum, returns or chases or improper sealing, where visible;

      (5) report as in need of repair deficiencies in the flue system components;

      (6) report as in need of repair a flue or vent pipe that does not properly terminate; and

      (7) report as in need of repair deficiencies in materials used for the venting systems.

    (w) Specific limitations for ducts and vents. The inspector is not required to do the following:

      (1) determine the efficiency, adequacy or capacity of the systems;

      (2) determine the uniformity of the supply of conditioned air to the various parts of the structure;

      (3) determine the types of materials contained in insulation, wrapping of pipes, ducts, jackets, boilers and wiring;

      (4) operate venting systems unless ambient temperatures or other circumstances, in the reasonable opinion of the inspector, are conducive to safe operation without damage to the equipment; or

      (5) operate a unit outside its normal operating range as reasonably determined by the inspector.

    (x) Plumbing systems. The inspector shall:

      (1) inspect and report as in need of repair deficiencies in the type and condition of all accessible and visible water supply and waste-water and vent pipes;

      (2) inspect and report as in need of repair deficiencies in the operation of all fixtures and faucets where the flow end of the faucet is not connected to an appliance;

      (3) report as in need of repair the lack of back-flow devices, anti-siphon devices or systems or air gaps when applicable;

      (4) report as in need of repair incompatible materials in connecting devices between differing metals in the supply system, where visible;

      (5) report as in need of repair deficiencies in water supply by viewing functional flow in two fixtures operated simultaneously;

      (6) report as in need of repair deficiencies in functional drainage at accessible plumbing fixtures;

      (7) report as in need of repair deficiencies in installation and identification of hot and cold faucets;

      (8) report as in need of repair mechanical drainstops that are missing or do not operate if installed on sinks, lavatories and tubs;

      (9) report as in need of repair commodes that have cracks in the ceramic material, are improperly mounted on the floor, leak or have tank components which do not operate;

      (10) report as in need of repair accessible supply and drain pipes that leak;

      (11) report as in need of repair the lack of a visible vent pipe system to the exterior of the structure or improper routing or termination of the vent system;

      (12) report as in need of repair a shower enclosure that leaks; and

      (13) report as in need of repair any exterior faucet attached or immediately adjacent to the structure that does not operate properly.

    (y) Specific limitations for plumbing systems. The inspector is not required to do the following:

      (1) operate any main, branch or shut-off valves;

      (2) inspect any system that has been shut down or otherwise secured;

      (3) inspect any components that are not visible or accessible;

      (4) inspect any exterior plumbing components such as water mains, private sewer systems, water wells, sprinkler systems or swimming pools;

      (5) inspect fire sprinkler systems;

      (6) inspect or operate drain pumps or waste ejector pumps;

      (7) inspect the quality or the volume of well water;

      (8) determine the potability of any water supply;

      (9) inspect water-conditioning equipment, such as softeners or filter systems;

      (10) inspect solar water heating systems;

      (11) determine the effectiveness of anti-siphon devices on appropriate fixtures or systems;

      (12) operate free-standing appliances;

      (13) inspect private water supply systems, swimming pools, or pressure tanks;

      (14) inspect the gas supply system for leaks; or

      (15) inspect for sewer clean-outs.

     

     

    RULE §535.230

     

    Standards of Practice: Inspection Guidelines for Electrical Systems

     

    (a) Service entrance and panels. The inspector shall:

      (1) inspect service entrance cables and report as in need of repair deficiencies in the integrity of insulation, drip loop, separation of conductors at weatherheads and clearances;

      (2) report as in need of repair a drop, weatherhead or mast that is not securely fastened;

      (3) report as in need of repair the lack of a grounding electrode conductor in the service where visible, or the lack of secure connection to the grounding electrode or grounding system;

      (4) report as in need of repair accessible main or subpanels that are not secured to the structure or appropriate for their location (weather-tight if exposed to weather, appropriate clearances and accessibility), do not have inside covers (dead fronts) in place, do not have conductors protected from the edges of metal panel boxes, do not have trip ties installed on labeled 240 volt circuits, do not have proper fasteners or do not have knockouts filled;

      (5) inspect and report as in need of repair deficiencies in the type and condition of the wiring in the panels, in the compatibility of overcurrent protectors for the size of conductor being used and in sizing of listed equipment of overcurrent protection and conductors, when power requirements for listed equipment are readily available and breakers are labeled;

      (6) report as in need of repair a panel that is installed in a hazardous location, such as a clothes closet;

      (7) report as in need of repair the absence of appropriate connections, such as copper/aluminum approved devices, pig-tailed connections or crimp connections; and the absence of anti-oxidants on aluminum conductor terminations; and

      (8) report as in need of repair the lack of main disconnect(s).

    (b) Specific limitations for service entrance and panels. The inspector is not required to do the following:

      (1) determine service capacity amperage or voltage or the capacity of the electrical system relative to present or future use;

      (2) determine the insurability of the property;

      (3) conduct voltage drop calculations; or

      (4) determine the accuracy of breaker labeling.

    (c) Branch circuits, connected devices and fixtures. The inspector shall:

      (1) report the type of branch circuit wiring;

      (2) inspect all accessible receptacles and report as in need of repair a receptacle in which:

        (A) power is not present;

        (B) polarity is incorrect;

        (C) the unit is not grounded, if applicable;

        (D) there is evidence of arcing or excessive heat;

        (E) the unit is not secured to the wall;

        (F) the cover is not in place; or

        (G) ground fault circuit interrupter devices are not properly installed as set forth by the current edition of the National Electric Code, publication 70A of the National Fire Protection Association, or do not operate properly as shown by use of a separate testing device;

      (3) operate all accessible wall and appliance switches and report as in need of repair a switch that:

        (A) does not operate or is damaged;

        (B) displays evidence of arcing or excessive heat; or

        (C) is not fastened securely with cover in place.

      (4) inspect installed fixtures including lighting devices and ceiling fans;

      (5) report as in need of repair an inoperable or missing fixture;

      (6) report as in need of repair deficiencies in exposed wiring, wiring terminations, junctions and junction boxes;

      (7) report as in need of repair deficiencies or absences of conduit in appropriate locations or conduit that is not terminated securely;

      (8) report as in need of repair appliances and electrical gutters that do not have proper bonding;

      (9) report as in need of repair subpanels that are not properly bonded and grounded;

      (10) report as in need of repair the lack of disconnects in appropriate locations;

      (11) inspect (if branch circuit aluminum wiring is discovered in the main or subpanels) a random sampling of accessible receptacles and switches and report as in need of repair the absence of appropriate connections, such as copper/aluminum approved devices, pig-tailed connections or crimp connections;

      (12) report as in need of repair the improper use of extension cords; and

      (13) report as in need of repair the absence of, or deficiencies in, the installation and operation of smoke or fire detectors not connected to a central alarm system.

     

     

    RULE §535.231

    Standards of Practice: Optional Systems

     

    (a) Scope. This section covers other systems and attachments that an inspector may inspect. The inspector may need special knowledge or tools to perform these inspections. It is the responsibility of the inspector to be properly informed and know current and safe procedures for inspecting the items described in this section. The inspector shall determine and provide a report of the condition of the equipment, systems, parts or components by visual observation and operation in normal modes and operating range noted at the date and time of the inspection. If an inspector agrees to inspect a component described in this section, §535.227 of this title (relating to Standards of Inspection: General Provisions) applies to the inspection.

    (b) Inspection guidelines for gas lines. The inspector shall:

      (1) inspect and report as in need of repair deficiencies in the condition and type of all accessible and visible gas piping; and

      (2) test gas lines by using a local or an industry-accepted procedure.

    (c) Specific limitations for gas lines. The inspector is not required to inspect sacrificial anode bonding or for its existence.

    (d) Inspection guidelines for outbuildings. The inspector shall:

      (1) inspect the building and report as in need of repair water penetration or deficiencies in structural performance; and

      (2) report as in need of repair deficiencies in electrical, plumbing, heating, ventilation or air-conditioning systems that the standards of practice would require the inspector to report for the principal structure.

    (e) Inspection guidelines for outdoor cooking equipment. The inspector shall:

      (1) report the energy source and operate the unit;

      (2) report as in need of repair deficiencies in operation, control knobs, handles, burner bars, grills, box, rotisserie (if present) and heat diffusion material;

      (3) report as in need of repair a unit or pedestal that is not stable;

      (4) report as in need of repair gas units that use improper materials for the gas branch line and the connection to the appliance; and

      (5) report as in need of repair a gas unit that has no shut-off valve, an inaccessible valve or a valve that leaks;

    (f) Inspection guidelines for lawn and garden sprinkler system. The inspector shall:

      (1) operate all zones or stations on the system manually;

      (2) report as in need of repair deficiencies in water flow or pressure at the circuit heads;

      (3) report as in need of repair surface water leaks, the absence or improper installation of anti-siphon valves and backflow preventers or the absence of shut-off valves;

      (4) inspect and report as in need of repair deficiencies in the condition and mounting of the control box and visible wiring; and

      (5) report as in need of repair deficiencies in the operation of each zone and associated valves, spray head patterns and areas of non-coverage within the zone.

    (g) Specific limitations for lawn and garden sprinkler system. The inspector is not required to inspect the automatic function of the timer or control box, the rain sensor or the effectiveness and sizing of anti-siphon valves or backflow preventers.

    (h) Inspection guidelines for private water wells. The inspector shall:

      (1) operate at least two fixtures simultaneously;

      (2) report the type of pump and type of storage equipment;

      (3) report as in need of repair deficiencies in water pressure and flow and operation of pressure switches;

      (4) inspect and report as in need of repair deficiencies in the condition of visible and accessible equipment and components;

      (5) report as in need of repair wiring that is improper or lacks circuit protection;

      (6) report as in need of repair deficiencies in the well head, including improper site drainage;

      (7) recommend, or arrange to have performed, a coliform analysis; and

      (8) report the proximity of any known septic system.

    (i) Specific limitations for private water wells. The inspector is not required to do the following:

      (1) open, uncover or remove the pump, heads, screens, lines or other component parts of the system;

      (2) determine water quality or potability or the reliability of the water supply or source; or

      (3) locate or verify underground water leaks.

    (j) Inspection guidelines for Individual private sewage systems (septic systems). The inspector shall:

      (1) report as in need of repair deficiencies in accessible or visible components of the system at the time of the inspection;

      (2) operate plumbing fixtures and report as in need of repair deficiencies in functional flow;

      (3) walk over the area of tanks and fields or beds and report as in need of repair any visual or olfactory evidence of effluent seepage or flow at the surface of the ground;

      (4) report as in need of repair areas of inadequate site drainage around or adjacent to the system;

      (5) report the proximity of any known water wells; underground cisterns; water supply lines; streams, ponds and lakes; sharp slopes or breaks; easement lines; property lines; soil absorption systems; swimming pools or sprinkler systems.

      (6) inspect the operation of the system;

      (7) report the lack of visible access to tanks;

      (8) report the type of the system, if possible, and the location of the drainfield; and

      (9) report as in need of repair aerators or dosing pumps that do not operate or equipment that is improperly wired.

    (k) Specific limitations for individual private sewage systems (septic systems). The inspector is not required to do the following:

      (1) excavate or uncover the system or its components to determine the size, adequacy or efficiency of the system; or

      (2) determine the type of construction used unless readily known without excavation or destructive examination.

    (l) Inspection guidelines for swimming pools and equipment (spas and hot tubs). The inspector shall:

      (1) report the type of pool construction;

      (2) report as in need of repair deficiencies in pool surfaces,

      (3) report as in need of repair deficiencies in tiles, copings and decks;

      (4) report as in need of repair deficiencies in slides, steps, diving boards and other equipment;

      (5) report as in need of repair deficiencies in drains, skimmers and valves;

      (6) report as in need of repair pool lights that are missing, do not function or lack ground fault circuit interrupter protection;

      (7) report as in need of repair pump motors, controls, and sweeps that do not function or lack proper wiring and circuit protection;

      (8) when inspecting a heater, report as in need of repair deficiencies that the standards of practice would require the inspector to report for a heating system;

      (9) report as in need of repair gas heaters that use improper materials for the branch line and the connection to the appliance;

      (10) report as in need of repair a gas unit that has no shut-off valve, an inaccessible valve or a valve that leaks;

      (11) report as in need of repair a pump motor, blower or other electrical equipment, if visible, that lacks external grounding;

      (12) report as in need of repair above-ground water leaks or deficiencies in the filter tank or pressure gauge; and

      (13) report as in need of repair the absence of, or deficiencies in, fences, gates or enclosures.

    (m) Specific limitations for swimming pools and equipment (spas and hot tubs). The inspector is not required to the following:

      (1) dismantle or otherwise open any components or lines;

      (2) uncover or excavate any lines or otherwise concealed components of the system or determine the presence of sub-surface leaks;

      (3) fill the pool, spa or hot tub with water;

      (4) determine the presence of sub-surface water tables; or

      (5) inspect ancillary equipment such as computer controls, covers, chlorinators or other chemical dispensers, or water ionization devices or conditioners other than required by this section.

     

 

Texas Administrative Code Chapter 304. Limited Statutory Warranty and Building and Performance Standards

(effective June 1, 2005)

 

 

TITLE 10

COMMUNITY DEVELOPMENT

PART 7

TEXAS RESIDENTIAL CONSTRUCTION COMMISSION

CHAPTER 304

WARRANTIES AND BUILDING AND PERFORMANCE STANDARDS

SUBCHAPTER A

GENERAL PROVISIONS

RULE §304.1

General Provisions

 


(a) Scope. This chapter describes the minimum standards of performance for the various elements or components of a home as described. Third-party inspectors appointed pursuant to §313.11 of this title will make recommendations for repair or replacement of those elements or components of a home that do not meet these standards during the applicable warranty period based upon the expected level of performance described in these standards for residential construction to which the standards apply. If an element or component of a home is not described particularly in this chapter, the element or component shall be constructed in accordance with any written agreement or, if there is no agreement, in accordance with usual and customary residential construction practices and the element or component shall perform for the purpose for which it is intended for the period of the applicable warranty. All home construction shall comply with applicable Codes.

(b) Effective Date. The provisions of this chapter shall apply to all applicable residential construction projects that must be registered with the commission pursuant to chapter 303, subchapter B, of this title if the construction commences on or after June 1, 2005. Construction commences on the earlier of the date that the parties enter into an agreement for a transaction governed by the Act or the date that work commences.

(c) Definitions. The following words and terms when used in this chapter shall have the following meanings, unless the context clearly indicates otherwise.

  (1) Adverse effect--A tangible condition that substantially impairs the functionality of the habitable areas of the home.

  (2) Builder Responsibility--A statement of the corrective action required by the builder to repair the construction defect and any other damage resulting from making the required repair. Parties may agree to an alternative remedy.

  (3) Code--The International Residential Code or, if the context requires, the National Electrical Code.

  (4) Electrical Standard--a standard contained in the version of the National Electrical Code (NEC), as follows:

    (A) for residential construction located in a municipality or the extraterritorial jurisdiction of a municipality, the version of the NEC applicable to electrical aspects of residential construction in the municipality under Local Government Code §214.214 and which is effective on the date of commencement of construction of the home;

    (B) for residential construction located in an unincorporated area not in the extraterritorial jurisdiction of a municipality, the version of the NEC applicable to electrical aspects of residential construction in the municipality that is the county seat of the county in which the construction is located and which is effective on the date of commencement of construction of the home; and

    (C) for residential construction located in an unincorporated area in a county that does not contain an incorporated area, the version of the NEC that existed on May 1, 2001.

  (5) Excessive or excessively--a quantity, amount or degree that exceeds that which is normal, usual or reasonable under the circumstance.

  (6) Exclusion--items, conditions or situations not warranted or not covered by a performance standard.

  (7) Extreme Weather Condition(s)--weather conditions in excess of or outside of the scope of the design criteria stated or assumed for the circumstance or locale in the Code.

  (8) The International Residential Code (IRC)--substantial compliance with the non-electrical standards contained in the version of the IRC for One- and Two-Family Dwellings published by the International Code Council (ICC) as follows:

    (A) for residential construction located in a municipality or the extraterritorial jurisdiction of a municipality, the version of the IRC applicable to non-electrical aspects of residential construction in the municipality under Local Government Code §214.212 and which is effective on the date of commencement of construction of the home;

    (B) for residential construction located in an unincorporated area not in the extraterritorial jurisdiction of a municipality, the version of the IRC applicable to non-electrical aspects of residential construction in the municipality that is the county seat of the county in which the construction is located and which is effective on the date of commencement of construction of the home; and

    (C) for residential construction located in an unincorporated area in a county that does not contain an incorporated area, the version of the IRC that existed on May 1, 2001.

  (9) Habitable Area--a living space as defined in §301.1(14) of this title.

  (10) Homeowner Responsibility--an action required by the homeowner for proper maintenance or care of the home or the element or component of the home concerned. A homeowner's failure to substantially comply with a stated homeowner responsibility creates an exclusion to the warranty for the performance standard.

  (11) Major Structural Components--the load-bearing portions of the following elements of a home:

    (A) Footings and Foundations;

    (B) Beams;

    (C) Headers;

    (D) Girders;

    (E) Lintels;

    (F) Columns (other than a column that is designed to be cosmetic);

    (G) Load-Bearing portions of walls and partitions;

    (H) Roof framing systems, to include ceiling framing;

    (I) Floor systems; and

    (J) Masonry Arches.

  (12) Manufactured Product--a component of the home that was manufactured away from the site of the home and that was installed in the home without significant modifications to the product as manufactured. Manufactured products commonly installed in residential construction include but are not limited to dishwashers, cook tops, ovens, refrigerators, trash compactors, microwave ovens, kitchen vent fans, central air conditioning coils and compressors, furnace heat exchangers, water heaters, carpet, windows, doors, light fixtures, fireplace inserts, pipes and electrical wires. For purposes of this chapter, a manufactured product includes any component of a home for which the manufacturer provides a warranty, provided that the manufacturer permits transfer of the warranty to the homeowner.

  (13) Original Construction Elevations--actual elevations of the foundation taken prior to substantial completion of the residential construction project. Such actual elevations shall include elevations of porches and garages if those structures are part of a monolithic foundation. To establish original construction elevations, elevations shall be taken at a rate of approximately one elevation per 100 square feet showing a reference point, subject to obstructions. Each elevation shall describe the floor. If no such actual elevations are taken then the foundation for the habitable areas of the home are presumed to be level +/- 0.75 inch (three-quarters of an inch) over the length of the foundation.

  (14) Performance Standard(s)--the standard(s) to which a home or an element or component of a home constructed as a part of new home construction or a material improvement or interior renovation must perform.

  (15) Span--the distance between two supports.

  (16) Substantial Completion--the later of:

    (A) the stage of construction when a new home, addition, improvement, or alteration to an existing home is sufficiently complete that the home, addition, improvement or alteration can be occupied or used for its intended purpose; or

    (B) if required, the issuance of a final certificate of inspection or occupancy by the applicable governmental authority.

(d) Resolving conflicts among standards. When an inconsistency exists between the Code, manufacturer's instructions and specifications, the standard required by the United States Department of Housing and Urban Development for Federal Housing Administration or Veterans Administration programs, ANSI/ASHRAE Standard (62.2-2003) or the commission-adopted performance standards, the most restrictive requirement shall apply.

 

RULE §304.2

General Provisions Applicable to all Residential Construction for New Homes, Material Improvements and Interior Renovations

 


(a) Builder Responsibilities for Compliance with Performance Standards and Repair Obligations.

  (1) Builder's Work. The builder is responsible for all work performed under the direction of the builder for the period of the applicable warranty. The builder is only responsible for construction defects about which the builder receives notice on or before the second anniversary of the date of discovery of the alleged construction defect but in no event later than thirty days following the applicable warranty period stated in §304.3(a) of this subchapter, unless otherwise expressly stated herein.

  (2) Repair of a construction defect. Any repair shall be performed in a manner and using such materials and methods as recommended by the third-party inspector in accordance with the inspector's duties under §313.14 of this title and consistent with the Code, the performance standard or in accordance with §304.2(a). In the event a third-party inspector determines that a construction defect is present but the inspector does not make a recommendation as to the procedure or method of repair, then the repair shall be in accordance with usual and customary building practices or as agreed by the parties. If the third-party inspector's report is appealed, then any repairs shall be performed in a manner and using such materials and methods as recommended by the appellate panel. If the appellate panel does not make a recommendation as to the procedure or method of repair, then the repair shall be made in accordance with the usual and customary business practices or as agreed by the parties.

  (3) Repair Condition. In connection with a repair of a construction defect, any repairs performed by the builder will include those components of the home that have to be removed or altered in order to repair the construction defect. Repair shall be made so that the condition is returned to its condition as it existed at the time immediately preceding the construction defect.

  (4) Finish. Surfaces altered incident to any repair will be finished or touched up to match the surrounding area as closely as practical. In connection with the repair of finish or surface material, such as paint, wallpaper, flooring or a hard surface, the builder will match the standard and grade as closely as reasonably possible. Builder will attempt to match the finish, but will not be responsible for discontinued patterns or materials, color variations or shade variations. When the surface finish material must be replaced and the original material has been discontinued, the builder is responsible for installing replacement material substantially similar in appearance to the original material.

  (5) Manufactured Products. The builder shall install all manufactured products in accordance with the manufacturer's instructions and specifications.

    (A) The builder shall use only new manufactured products and parts unless otherwise agreed in writing by the parties. If the builder did not install a manufactured product in accordance with the manufacturer's specifications or use newly manufactured parts as required, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall notify the builder of a known construction defect not later than the second anniversary of the date of discovery of the construction defect or not later than thirty days following the applicable warranty period provided in §304.3(a) of this subchapter.

  (6) Specialty Feature. Notwithstanding a performance standard stated in this chapter, a specialty feature, which is work performed or material supplied incident to certain design elements shown on the construction plans and specifications and agreed to in writing by the builder and the homeowner, shall be deemed to be compliant with the performance standards stated in this chapter so long as all items are compliant with the Code.

(b) Exceptions and Exclusions from Builder's Responsibilities.

  (1) The builder is not responsible for repair, loss or damage to a component or that part of a component of a home caused by or made worse by any of the following:

    (A) Work performed or material supplied incident to construction, modification or repair to the home performed by anyone other than the builder or persons providing work or material at the direction of the builder.

    (B) The negligence, improper maintenance, misuse, abuse, failure to follow manufacturer's recommendations, failure to take reasonable action to mitigate damage, failure to take reasonable action to maintain the residence or other action or inaction of anyone other than the builder or persons providing work or material at the direction of the builder.

    (C) Failure of the homeowner to comply with the homeowner's responsibilities as set forth in subsection (c) of this section or as may be stated separately elsewhere in this chapter.

    (D) Alterations to the grade of the soil that are not in compliance with the Code or applicable governmental regulations.

    (E) Normal wear and tear or normal deterioration to any component of the home.

    (F) Extreme weather conditions.

    (G) Riot, civil commotion, war, terrorism, vandalism, aircraft, vehicle or boat.

    (H) Fire, smoke or water damage unless such loss or damage is a direct result of a construction defect.

    (I) Change in the underground water table that exerts pressure on, seeps, or leaks under the home, sidewalk, driveway, foundation or other structure or causes subsidence or sinkholes.

    (J) Erosion or accretion of soils unless such loss or damage is a direct result of a construction defect.

    (K) Insects, birds, rodents, vermin or other wild or domestic animals unless such loss or damage is a direct result of a construction defect.

    (L) The quality and potability of water unless caused by a construction defect.

    (M) While the home is being used primarily for nonresidential purposes.

    (N) Use for which the home or the component of the home was not designed.

    (O) Use that exceeds the normal design loads prescribed by the Code or the engineer of record.

    (P) Homeowner delay in reporting a known construction defect or failing to take reasonable action necessary to prevent further damage to the home.

    (Q) For remodeling projects, improvements, alterations or additions to an existing residence where the performance standard cannot be achieved due to an existing condition.

    (R) Abuse or misuse of a home component or manufactured product by anyone other than the builder or persons providing work or material at the direction of the builder.

  (2) No Actual Physical Damage. The builder shall not be responsible for any condition that does not result in actual physical damage to the home, including, but not limited to the presence of radon gas, formaldehyde or other pollutants or contaminants, or the presence or effect of mold, mildew, toxic material, or volatile organic compound, unless such condition is a direct result of a construction defect.

(c) Homeowner's Responsibilities.

  (1) Home Maintenance. Maintenance of the home and the lot on which the home is located are essential to the proper functioning of the home. The homeowner is responsible for maintenance of the home and the lot on which it is located. The homeowner is responsible for maintenance items described in this paragraph and those maintenance items identified separately in the performance standards set forth in this chapter. Additionally, the homeowner is responsible for ongoing maintenance responsibilities that affect the performance of the home but that may not be expressly stated in this chapter. Such ongoing maintenance responsibilities include, but are not limited to, periodic repainting and resealing of finished surfaces as necessary, caulking for the life of the home, regular maintenance of mechanical systems, regular replacement of HVAC filters, cleaning and proper preservation of grading around the home and drainage systems to allow for the proper drainage of water away from the home.

  (2) Manufactured Products. The homeowner shall use and perform periodic maintenance on all manufactured products according to the manufacturer's instructions and specifications. The misuse, abuse, neglect or other failure to follow manufacturer's specifications with regard to manufactured products may void the manufacturer's warranty.

  (3) Landscape Planting. The homeowner shall take measures to prevent landscaping materials or plants from contacting the exterior surface of the home and from interfering with the proper drainage of water away from the foundation. The homeowner should not improperly alter the proper drainage pattern or grade of the soil within ten feet of the foundation so that it negatively impacts the home's performance or fails to comply with the Code.

  (4) Humidity or Dryness in the Home. The homeowner should take the following actions to prevent excessive moisture accumulation by:

    (A) properly using ventilation equipment;

    (B) preventing excessive temperature fluctuation; and

    (C) taking any other action reasonably necessary to avoid excessive moisture, dampness, humidity or condensation in the home that may lead to damage due to excessive moisture or dryness.

  (5) Proper Maintenance and Care of Home Components. The homeowner shall properly maintain each component of the home including proper cleaning, care and upkeep of the home. The homeowner shall use home components for the purposes for which they are intended and shall not damage, misuse or abuse home components.

  (6) Self-Help. Upon observation of a circumstance that may cause further damage to the home or a component of the home, the homeowner shall take reasonable action necessary to prevent further damage to the home.

 

RULE §304.3

Limited Warranties

 

Texas Administrative Code

 

TITLE 10

COMMUNITY DEVELOPMENT

PART 7

TEXAS RESIDENTIAL CONSTRUCTION COMMISSION

CHAPTER 304

WARRANTIES AND BUILDING AND PERFORMANCE STANDARDS

SUBCHAPTER B

PERFORMANCE STANDARDS FOR COMPONENTS OF A HOME SUBJECT TO A MINIMUM WARRANTY OF ONE YEAR FOR WORKMANSHIP AND MATERIALS

RULE §304.10

Performance Standards for Foundations and Slabs

 


(a) Performance Standards for Raised Floor Foundations or Crawl Spaces.

  (1) A crawl space shall be graded and drained properly to prevent surface run-off from accumulating deeper than two inches in areas 36 inches or larger in diameter. Exterior drainage around perimeter crawl space wall shall not allow water to accumulate within ten feet of the foundation for more than 24 hours after a rain except in a sump that drains other areas.

    (A) If the crawl space is not graded or does not drain in accordance with the performance standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall not modify improperly the existing grade or allow water from an irrigation system to cause water to accumulate excessively under the foundation. The homeowner shall not allow landscape plantings to interfere with proper drainage away from the foundation. The homeowner shall not use the crawl space for storage of any kind.

  (2) Water shall not enter through the basement or crawl space wall or seep through the basement floor.

    (A) If water enters the basement or crawl space wall or seeps through the basement floor, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (2) of this subsection.

    (B) The homeowner shall not modify improperly the existing grade or allow water from an irrigation system to cause water to accumulate excessively near the foundation. The homeowner shall not allow landscape plantings to interfere with proper drainage away from the foundation.

(b) Performance Standards for Concrete Slab Foundations, excluding Finished Concrete Floors.

  (1) Concrete floor slabs in living spaces that are not otherwise designed with a slope for drainage, such as a laundry room, shall not have excessive pits, depressions or unevenness equal to or exceeding 3/8 of an inch in any 32 inches and shall not have separations or cracks that equal or exceed 1/8 of an inch in width or 1/16 of an inch in vertical displacement. If a concrete floor slab in a living space fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within that standard.

  (2) Concrete slabs shall not have protruding objects, such as a nail, rebar or wire mesh. If a concrete slab has a protruding object, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (3) A separation in an expansion joint in a concrete slab shall not equal or exceed 1/4 of an inch vertically or one inch horizontally from an adjoining section. If an expansion joint in a concrete slab fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Exterior Concrete including Patios, Stem Walls, Driveways, Stairs or Walkways.

  (1) Concrete corners or edges shall not be damaged excessively due to construction activities. If a concrete corner or edge is damaged excessively, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (2) A crack in exterior concrete shall not cause vertical displacement equal to or in excess of 1/4 of an inch or horizontal separation equal to or excess of 1/4 of an inch.

    (A) If an exterior concrete slab is cracked, separated or displaced beyond the standard of performance stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall not over-water surrounding soil or allow the surrounding soil to become excessively dry. The homeowner shall not allow heavy equipment to be placed on the concrete.

  (3) The finish on exterior concrete shall not be excessively smooth, so that the surface becomes slippery.

    (A) If the finish on exterior concrete is excessively smooth so that the surface becomes slippery, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (3) of this subsection.

    (B) A concrete surface that has been designed to be smooth is excepted from this performance standard.

  (4) Exterior concrete shall not contain a protruding object, such as a nail, rebar or wire mesh. If an exterior concrete surface has a protruding object, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (5) A separation in an expansion joint in an exterior concrete shall not equal or exceed 1/2 of an inch vertically from an adjoining section or one inch horizontally, including joint material. If an expansion joint fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) A separation in a control joint shall not equal or exceed 1/4 of an inch vertically or 1/2 of an inch horizontally from an adjoining section. If a control joint fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Concrete stair steepness and dimensions, such as tread width, riser height, landing size and stairway width shall comply with the Code. If the steepness and dimensions of concrete stairs do not comply with the Code, the builder shall take such action as is necessary to bring the variance within the standard for Code compliance.

  (8) Handrails shall remain securely attached to concrete stairs. If handrails are not firmly attached to the concrete stairs, the builder shall take such steps necessary as to attach the rails securely.

  (9) Concrete stairs or stoops shall not settle or heave in an amount equal to or exceeding 3/8 of an inch. Concrete stairs or stoops shall not separate from the home in an amount equal to or exceeding one inch, including joint material. If the stairs or stoops settle or heave, or separate from the home in an amount equal to or exceeding the standard above builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (10) A driveway will not have a negative slope unless due to site conditions, the lot is below the road. If a driveway has a negative slope due to site conditions, it shall have swales or drains properly installed to prevent water from entering into the garage. If a driveway has a negative slope that allows water to enter the garage in normal weather conditions, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (11) Concrete floor slabs in detached garages, carports or porte-cocheres shall not have excessive pits, depressions, deterioration or unevenness. Separations or cracks in these slabs shall not equal or exceed 3/16 of an inch in width, except at expansion joints, or 1/8 of an inch in vertical displacement. If a concrete floor slab in a detached garage, carport or porte-cochere does not meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.11

Performance Standards for Framing

 


(a) Building and Performance Standard for Walls.

  (1) Walls shall not bow or have depressions that equal or exceed 1/4 of an inch out of line within any 32-inch horizontal measurement as measured from the center of the bow or depression or 1/2 of an inch within any eight-foot vertical measurement. If a wall does not meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Walls shall be level, plumb and square to all adjoining openings or other walls within 3/8 of an inch in any 32-inch measurement. If a wall does not meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A crack in a beam or a post shall not equal or exceed 1/2 of an inch in width at any point along the length of the crack. If a crack in the beam or post fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) A non-structural post or beam shall not have a warp or twist equal or exceeding one inch in eight-feet of length. Warping or twisting shall not damage beam pocket. If a non-structural post or beam fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) Exterior sheathing shall not delaminate or swell.

    (A) If exterior sheathing delaminates or swells, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (5) of this subsection.

    (B) The homeowner shall not make penetrations in the exterior finish of a wall that allow moisture to come in contact with the exterior sheathing.

  (6) An exterior moisture barrier shall not allow an accumulation of moisture inside the barrier.

    (A) If an exterior moisture barrier allows an accumulation of moisture inside the barrier, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (6) of this subsection.

    (B) The homeowner shall not make penetrations through the exterior moisture barrier that permit the introduction of moisture inside the barrier.

(b) Performance Standards for Ceilings. A ceiling shall not bow or have depressions that equal or exceed 1/2 of an inch out of line within a 32-inch measurement as measured from the center of the bow or depression running parallel with a ceiling joist. If a ceiling has a bow or depression that is greater than the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Sub-floors.

  (1) Under normal residential use, the floor shall not make excessive squeaking or popping sounds. If the floor makes excessive squeaking and popping sounds under normal residential use, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (2) Sub-floors shall not delaminate or swell to the extent that it causes observable physical damage to the floor covering or visually affects the appearance of the floor covering. Exposed structural flooring, where the structural flooring is used as the finished flooring, is excluded from the standard stated in this paragraph. If a sub-floor delaminates or swells to the extent that it affects the flooring covering as stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Sub-flooring shall not have excessive humps, ridges, depressions or slope within any room that equals or exceeds 3/8 of an inch in any 32-inch direction. If the sub-flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Performance Standards for Stairs.

  (1) Stair steepness and dimensions such as tread width, riser height, landing size and stairway width, shall comply with the Code. If stair steepness and dimensions do not comply with the Code, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (2) Under normal residential use, stairs shall not make excessive squeaking or popping sounds. If stairs make excessive squeaking and popping sounds under normal residential use, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

RULE §304.12

Performance Standards for Drywall

 

 

(a) A drywall surface shall not have a bow or depression that equals or exceeds 1/4 of an inch out of line within any 32-inch horizontal measurement as measured from the center of the bow or depression or 1/2 of an inch within any eight-foot vertical measurement. If a drywall surface fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(b) A ceiling made of drywall shall not have bows or depressions that equal or exceed 1/2 of an inch out of line within a 32-inch measurement as measured from the center of the bow or depression running parallel with a ceiling joist or within 1/2 of an inch deviation from the plane of the ceiling within any eight-foot measurement. If a drywall ceiling fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A drywall surface shall not have a crack such that any crack equals or exceeds 1/32 of an inch in width at any point along the length of the crack. If a drywall surface has a crack that exceeds the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Crowning at a drywall joint shall not equal or exceed 1/4 of an inch within a twelve-inch measurement centered over the drywall joint. If crowning at a drywall joint exceeds the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard. Crowning occurs when a drywall joint is higher than the plane of the drywall board on each side.

(e) A drywall surface shall not have surface imperfections such as blisters, cracked corner beads, seam lines, excess joint compound or trowel marks that are visible from a distance of six feet or more in normal light. If a drywall surface fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(f) A drywall surface shall not be out of level (horizontal), plumb (vertical) or square (perpendicular at a 90-degree angle) such that there are variations in those measurements to wall or surface edges at any opening, corner, sill, shelf, etc. shall not equal or exceed 3/8 of an inch in any 32-inch measurement along the wall or surface.

  (1) If a drywall surface fails to meet the standard stated in subsection (f) of this section, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) This standard shall not apply to remodeling projects where existing conditions do not permit the builder to achieve the performance standard. At or about the time of discovery of such a preexisting condition, a remodeler shall notify the homeowner, in writing, of any existing condition that prevents achievement of the standard.

(g) Nails or screws shall not be visible in a drywall surface. If nails or screws are visible, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.13

Performance Standards for Insulation

 


(a) Insulation shall be installed in the walls, ceilings and floors of a home in accordance with the building plan and specifications and the Code. If the insulation in walls, ceilings or floors is not in accordance with the building plans and specifications and the Code, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(b) Blown insulation in the attic shall not displace or settle so that it reduces the R-value below manufacturer's specifications, the building plans and the Code. If the blown insulation in the attic reduces, settles or is displaced to the extent that the R-value is below the manufacturer's specifications, the building plans and Code, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(c) A gap equal to or in excess of 1/4 of an inch between insulation batts or a gap between insulation batts and framing members is not permitted. If a gap equal to or greater than 1/4 of an inch occurs between insulation batts or a gap occurs between an insulation batt and a framing member, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(d) Insulation shall not cover or block a soffit vent to the extent that it blocks the free flow of air. If the insulation covers or blocks the soffit vent, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

RULE §304.14

Performance Standards for Exterior Siding and Trim

 


(a) Performance Standards for Exterior Siding.

  (1) Exterior siding shall be equally spaced and properly aligned. Horizontal siding shall not equal or exceed 1/2 of an inch off parallel with the bottom course or 1/4 of an inch off parallel with the adjacent course from corner to corner. If siding is misaligned or unevenly spaced and fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Siding shall not gap or bow. A siding end joint shall not have a gap that equals or exceeds 1/4 of an inch in width. Siding end joint gaps shall be caulked. A bow in siding shall not equal or exceed 3/8 of an inch out of line in a 32-inch measurement. If siding has gaps or bows that exceed the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Nails shall not protrude from the finished surface of siding but nail heads may be visible on some products where allowed by the manufacturer's specifications. If a nail protrudes from the finished surface of siding, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (4) Siding shall not have a nail stain. If siding has a nail stain, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (5) Siding and siding knots shall not become loose or fall off. If siding or siding knots become loose or fall off, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (6) Siding shall not delaminate. If siding fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Siding shall not cup in an amount equal to or exceeding 1/4 of an inch in a six-foot run. If siding fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (8) Siding shall not have cracks or splits that equal or exceed 1/8 of an inch in width. If siding fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Exterior Trim.

  (1) A joint between two trim pieces shall not have a separation at the joint equal to or exceeding 1/4 of an inch in width and all trim joints shall be caulked. If there is a separation at a trim joint that fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Exterior trim and eave block shall not warp in an amount equal to or exceeding 1/2 of an inch in an eight-foot run. If exterior trim or eave block warps in excess of the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Exterior trim and eave block shall not cup in an amount equal to or in excess of a 1/4 of an inch in a six-foot run. If exterior trim or eave block cups in excess of the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Exterior trim and eave block shall not have cracks or splits equal to or in excess of 1/8 of an inch in average width. If exterior trim or eave block has cracks in excess of the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) Trim shall not have nails that completely protrude through the finished surface of the trim but nail heads may be visible on some products.

    (A) If a nail protrudes from the finished surface of the trim, the builder shall take such action as is necessary to bring the variance within the standard within the standard stated in paragraph (5) of this subsection.

    (B) Some products specify that the nails be flush with the trim surface. When these products are used, visible nail heads are not considered protruding nails as long as they are painted over.

  (6) Trim shall not have a nail stain. If trim has a nail stain, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

RULE §304.15

Performance Standards for Masonry including Brick, Block and Stone

 


(a) A masonry wall shall not bow in an amount equal to or in excess of one inch when measured from the base to the top of the wall.

  (1) If a masonry wall fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The standard set forth in this subsection does not apply to natural stone products.

(b) A masonry unit or mortar shall not be broken or loose. If a masonry unit or mortar fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A masonry mortar crack shall not equal or exceed 1/8 of an inch in width. If a crack in masonry mortar fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(d) A masonry unit or mortar shall not deteriorate. If a masonry unit or mortar fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(e) Masonry shall not have dirt, stain or debris on the surface due to construction activities. If masonry fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(f) A gap between masonry and adjacent material shall not equal or exceed 1/4 of an inch in average width and all such gaps shall be caulked. If a gap between masonry and adjacent material fails to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(g) Mortar shall not obstruct a functional opening, such as a vent, weep hole or plumbing cleanout.

  (1) If the mortar obstructs a functional opening, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

  (2) The homeowner shall not put any material into weep holes. Weep holes are an integral part of the wall drainage system and must remain unobstructed.

RULE §304.16

Performance Standards for Stucco

 


(a) Stucco surfaces shall not be excessively bowed, uneven, or wavy.

  (1) If a stucco surface fails to perform as stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) This standard shall not apply to decorative finishes.

(b) Stucco shall not be broken or loose. If stucco is broken or loose, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(c) Stucco shall not have cracks that equal or exceed 1/8 of an inch in width at any point along the length of the crack.

  (1) If the stucco fails to perform as stated in subsection (c) of this section, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The builder shall not be responsible for repairing cracks in stucco caused by the homeowner's actions, including the attachment of devices to the stucco surface, such as, but not limited to, patio covers, plant holders, awnings and hose racks.

(d) Stucco shall not deteriorate excessively.

  (1) If the stucco deteriorates excessively, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The homeowner shall not allow water from irrigation systems to contact stucco finishes excessively.

(e) Stucco shall not have dirt, stain or debris on surface due to construction activities. If the stucco fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(f) Stucco surfaces shall not have imperfections that are visible from a distance of six feet under normal lighting conditions that disrupt the overall uniformity of the finished pattern. If the stucco fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(g) The lath shall not be exposed. If the lath is exposed, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(h) A separation between the stucco joints shall not equal or exceed 1/16 of an inch in width. If a separation between the stucco joints occurs in excess of the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(i) A separation between a stucco surface and adjacent material shall not equal or exceed 1/4 of an inch in width and all separations shall be caulked. If a separation occurs between a stucco surface and adjacent material occurs in excess of the standard stated in this subsection or if such a separation is not caulked, the builder shall take such action as is necessary to bring the variance within the standard.

(j) Stucco shall not obstruct a functional opening, such as a vent, weep hole or plumbing cleanout. If stucco obstructs a functional opening, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(k) Stucco screed shall have a minimum clearance of at least 4 inches above the soil or landscape surface and at least 2 inches above any paved surface. If the stucco screed clearance does not meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(l) Exterior Installation Finish Systems (EIFS) stucco screed shall clear any paved or unpaved surface by 6 inches. If the EIFS stucco screed clearance does not meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.17

Performance Standards for Roofs

 


(a) Flashing shall prevent water penetration.

  (1) If the flashing fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The builder shall not be responsible for leaks caused by extreme weather.

(b) The roof shall not leak.

  (1) If the roof fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The builder shall not be responsible for leaks caused by extreme weather.

  (3) The homeowner shall perform periodic maintenance to prevent leaks due to build-up of debris, snow or ice. The homeowner shall take such action as is necessary to prevent downspouts and gutters from becoming clogged.

(c) A vent, louver or other installed attic opening shall not leak.

  (1) If a vent, louver or other installed attic opening fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The builder shall not be responsible for leaks caused by extreme weather.

(d) A gutter or downspout shall not leak or retain standing water. After cessation of rainfall, standing water in an unobstructed gutter shall not equal or exceed 1/2 of an inch in depth.

  (1) If a gutter or downspout fails to meet the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The builder shall not be responsible for leaks caused by extreme weather.

  (3) The homeowner shall maintain and clean gutters and downspouts to prevent buildup of debris or other obstructions.

(e) Shingles, tiles, metal or other roofing materials shall not become loose or fall off in wind speeds less than those set forth in the manufacturer's specifications. If the shingles, tiles, metal or other roofing materials fail to meet the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(f) A skylight shall not leak. If a skylight fails to meet the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(g) Water shall drain from a built-up roof within two hours after cessation of rainfall. The standard does not require that the roof dry completely within the time period. If the built-up roof fails to meet the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(h) A roof tile shall not be cracked or broken. No shingle shall be broken so that it detracts from the overall appearance of the home. If roof tiles or shingles fail to meet the standard in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(i) A pipe, vent, fireplace or other object designed to penetrate the roof shall not be located within the area of roof valley centerline without proper "cricketing" or other Code-approved water diversion methods. If a pipe, vent, fireplace or other object designed to penetrate the roof is not correctly located as provided in the performance standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(j) The exterior moisture barrier of the roof shall not allow moisture penetration.

  (1) If the exterior moisture barrier fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The homeowner shall not make penetrations through exterior moisture barrier of the roof.

RULE §304.18

Performance Standards for Doors and Windows

 


(a) Performance Standards for Both Doors and Windows.

  (1) When closed, a door or window shall not allow excessive infiltration of air or dust. If a door or window fails to meet the performance standard stated in this paragraph the builder shall take such action as is necessary to bring the variance within the standard.

  (2) When closed, a door or window shall not allow excessive accumulation of moisture inside the door or window.

    (A) If a door or window fails to meet the performance standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall keep weep holes on windows and doors free of dirt buildup and debris, thereby allowing water to drain properly.

    (C) Most door and window assemblies are designed to open, close and weep moisture--allow condensation or minor penetration by the elements to drain outside.

  (3) Glass in doors and windows shall not be broken due to improper installation or construction activities. If glass in a window or door is broken due to improper installation or construction activities, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (4) A screen in a door or window shall fit properly and shall not be torn or damaged due to construction activities. A screen shall not have a gap equal to or exceeding 1/4 of an inch between the screen frame and the window frame. If a screen in a door or window fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) There shall be no condensation between window and door panes in a sealed insulated glass unit.

    (A) If a window or door fails to meet the performance standard stated in paragraph (5) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall not apply a tinted window film or coating to window or door panes in sealed insulated glass units.

  (6) A door or window latch or lock shall close securely and shall not be loose or rattle. If a door, window latch or lock fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) A door or window shall operate easily and smoothly and shall not require excessive pressure when opening or closing. If a door or window fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (8) A door or window shall be painted or stained according to the manufacturers' specifications. If a window or door fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Windows. A double hung window shall not move more than two inches when put in an open position. If a window fails to meet the performance standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Doors.

  (1) A sliding door and door screen shall stay on track.

    (A) If a sliding door or door screen fails to perform to the standard stated in paragraph (1) of this subsection, builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall clean and lubricate sliding door or door screen hardware as necessary.

  (2) The spacing between an interior door bottom and original floor covering, except closet doors, shall not exceed 1.5 inches and shall be at least 1/2 of an inch. The spacing between an interior closet door bottom and original floor covering shall not exceed two inches and shall be at least 1/2 of an inch. If the spacing between a door bottom and the original floor covering does not meet the performance standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A door shall not delaminate. If a door becomes delaminated, a builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (4) A door panel shall not split so that light from the other side is visible. If a door panel fails to meet the performance standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) A door shall open and close without binding. If a door fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) A door shall not warp to the extent that it becomes inoperable. A warp in a door panel shall not equal or exceed 1/4 of an inch from original dimension measured vertically, horizontally or diagonally from corner to corner. If a door fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) A storm door shall open and close properly and shall fit properly. If a door fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (8) When a door is placed in an open position, it shall remain in the position it was placed, unless the movement is caused by airflow. If a door fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (9) A metal door shall not be dented or scratched due to construction activities. If a metal door fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Performance Standards for Garage Doors.

  (1) A metal garage door shall not be dented or scratched due to construction activities. If a metal garage door fails to comply with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) A garage door opener, if provided, shall operate properly in accordance with manufacturer's specifications.

    (A) If a garage door opener fails to perform in accordance with the standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) A homeowner shall maintain tracks, rollers and chains and shall not block or bump sensors to electric garage door openers.

  (3) A garage door shall not allow excessive water to enter the garage and the gap around the garage door shall not equal or exceed 1/2 of an inch in width. If a garage door allows excessive water to enter the garage or the gap around the garage door equals or exceeds 1/2 of an inch, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (4) A garage door spring shall operate properly and shall not lose appreciable tension, break or be undersized. If a garage door spring fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) A garage door shall remain in place at any open position, operate smoothly and not be off track. If a garage door fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.19

Performance Standards for Interior Flooring

 


(a) Performance Standards for Carpet, Vinyl Flooring and Wood Flooring. Performance standards for ceramic tile, flagstone, marble, granite, slate, quarry tile other hard surface floors, except finished concrete floors, are located in §304.20 of this subchapter.

(b) Performance Standards for Carpet.

  (1) Carpet shall not wrinkle and shall remain tight, lay flat and be securely fastened. If the carpet fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Carpet seams shall be smooth without a gap or overlap. If the carpet fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Carpet shall not be stained or spotted due to construction activities. If the carpet fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Finished Concrete Floor.

  (1) A finished slab, located in a living space that is not otherwise designed for drainage, shall not have pits, depressions or unevenness that equals or exceeds 3/8 of an inch in any 32 inches.

    (A) If a finished concrete slab in a living space fails to meet the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) Finished concrete slabs in living spaces that are designed for drainage, such as a laundry room, are excepted from the standards stated in paragraph (1) of this subsection.

  (2) Finished concrete slabs in living spaces shall not have separations, including joints, and cracks that equal or exceed 1/8 of an inch in width or 1/16 of an inch in vertical displacement. If a finished concrete slab in a living space fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Performance Standards for Wood Flooring.

  (1) Wood flooring shall not have excessive humps, depressions or unevenness that equals or exceeds 3/8 of an inch in any 32-inch direction within any room. If wood flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Wood flooring shall remain securely attached to the foundation or sub-floor unless the wood flooring is designed to be installed without nails, glue, adhesives or fasteners. If wood flooring fails to meet the standards of this, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Wood flooring shall not have open joints and separations that equal or exceed 1/8 of an inch.

    (A) If wood flooring fails to meet the standards of paragraph (3) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) These standards do not apply to non-hardwood species that contain greater moisture and may shrink after installation or structural floors that are designed to serve as the finished floor. If the floor is designed as a structural finish floor, the builder must provide a written explanation of the characteristics of that floor to the homeowner prior to the execution of the contract.

  (4) Strips of floorboards shall not cup in an amount that equals or exceeds 1/16 of an inch in height in a three-inch distance when measured perpendicular to the length of the board.

    (A) If the wood flooring fails to meet the standard stated in paragraph (4) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) This standard does not apply to non-hardwood species that typically shrink after installation or structural floors that are designed to serve as the finished floor. If the floor is designed as a structural finish floor, the builder must provide a written explanation of the characteristics of that floor to the homeowner.

  (5) Unless installed as a specialty feature, wood flooring shall not have excessive shade changes or discoloration due to the construction activities of the builder. If the wood floor fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) Unless installed as a specialty feature, wood flooring shall not be stained, spotted or scratched due to construction activities of the builder. If wood flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(e) Performance Standards for Vinyl Flooring.

  (1) Vinyl flooring shall be installed square to the most visible wall and shall not vary by 1/4 of an inch in any six-foot run. If the vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The seam alignment in vinyl flooring shall not vary such that the pattern is out of alignment in an amount that equals or exceeds 1/8 of an inch. If the vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Vinyl flooring shall remain securely attached to the foundation or sub-floor. If the vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) A vinyl floor shall not have a depression that equals or exceeds 1/2 of an inch in any six-foot run. If a vinyl floor has a depression that exceeds the standard stated in this paragraph and the depression is due to construction activities, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) A vinyl floor shall not have a ridge that equals or exceeds 1/2 of an inch when measured as provided in this paragraph. The ridge measurement shall be made by measuring the gap created when a six-foot straight edge is placed tightly three inches on each side of the defect and the gap is measured between the floor and the straight edge at the other end. If a vinyl floor has a ridge that fails to comply with the standard stated in this paragraph and the ridge is due to construction activities, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) Vinyl floor shall not be discolored, stained or spotted due to the construction activities of the builder. If the vinyl floor fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Vinyl flooring shall not be scratched, gouged, cut or torn due to construction activities. If the vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (8) Debris, sub-floor seams, nails and/or screws shall not be detectable under the vinyl floor from a distance of three feet or more in normal light. If the vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (9) Sub-flooring shall not cause vinyl flooring to rupture. If vinyl flooring fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (10) A seam in vinyl flooring shall not have a separation that equals or exceeds 1/16 of an inch in width. Where dissimilar materials abut, there shall not be a gap equal to or greater than 1/8 of an inch. If vinyl flooring fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.20

Performance Standards for Hard Surfaces, including Ceramic Tile, Flagstone, Marble, Granite, Slate, Quarry Tile, Finished Concrete or Other Hard Surfaces

 


(a) Performance Standards for Hard Surfaces Generally.

  (1) A hard surface shall not break or crack due to construction activities. If a hard surface is cracked or broken due to construction activities, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) A hard surface shall remain secured to the substrate. If a hard surface fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A surface imperfection in floor hard surface shall not be visible from a distance of three feet or more in normal light. A surface imperfection in non-floor hard surface shall not be visible from a distance of two feet or more in normal light. If a hard surface fails to meet the standards stated in this paragraph due to construction activities, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Color variations between field hard surfaces and trim hard surfaces should not vary excessively due to construction activities.

    (A) If color variations between field and trim hard surfaces are excessive and are due to construction activities, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (4) of this subsection.

    (B) Natural products such as flagstone, marble, granite, slate and other quarry tile will have color variation.

  (5) Hard surface areas shall not leak. If a hard surface area fails to perform in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) The surfaces of two adjacent hard surfaces shall not vary in an amount equal to or exceeding 1/16 of an inch displacement at a joint, with the exception of transition trim pieces. If a joint between two hard surfaces fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Hard surface layout or grout line shall not be excessively irregular.

    (A) If hard surface layouts or grout lines fail to meet the performance standard stated in paragraph (7) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) Natural products such as flagstone, marble, granite, slate, and other quarry tile will have size variations that may create irregular layouts or grout lines.

  (8) Hard surface countertops shall be level to within 1/4 of an inch in any six-foot measurement. If a hard surface countertop is not level to within the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Grout.

  (1) Grout shall not crack or deteriorate. If grout fails to meet the performance standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Grout shall not change shade or discolor excessively due to construction activities. If grout fails to perform to the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Concrete Countertops.

  (1) A concrete countertop shall not have excessive pits, depressions, or unevenness that equal or exceed 1/8 of an inch in any 32-inch measurement. If a concrete countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) A concrete countertop shall not have separations or cracks equal to or exceeding 1/16 of an inch in width or 1/64 of an inch in vertical displacement. If a concrete countertop fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A finished concrete countertop shall not be stained, spotted or scratched due to construction activities. If a concrete countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) A concrete countertop shall not have a chipped edge that extends beyond 1/16 of an inch from the edge of the countertop due to construction activities. If a concrete countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) A concrete countertop shall not change shade or discolor excessively due to construction activities. If a concrete countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.21

Performance Standards for Painting, Stain and Wall Coverings

 


(a) Performance Standards for Caulking. Interior caulking shall not deteriorate or crack excessively. If the interior caulking fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Painting and Stain.

  (1) Paint or stain shall not have excessive color, shade or sheen variation.

    (A) If the paint or stain fails to meet the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) This standard shall not apply to stained woodwork.

  (2) Paint shall cover all intended surfaces so that unpainted areas shall not show through paint when viewed from a distance of six feet in normal light. If the painting fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Interior paint or stain shall not deteriorate. If paint or stain fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Exterior paint or stain shall not deteriorate excessively. If paint or stain fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) Paint over-spray shall not exist on any surface for which it was not intended. If the paint is sprayed onto a surface for which it was not intended, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (6) Interior varnish, polyurethane or lacquer finish shall not deteriorate. If an interior finish fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard. If an interior finish fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Exterior varnish, polyurethane or lacquer finishes shall not deteriorate excessively.

    (A) If an exterior finish fails to meet the standard stated in paragraph (7) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) Exterior varnish, polyurethane or lacquer finishes that are subject to direct sunlight are excluded from this standard.

  (8) Interior painted, varnished or finished surface shall not be scratched, dented, nicked or gouged due to construction activities. If interior painted, varnished or finished surfaces fail to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (9) A paint product shall perform as represented by the manufacturer to meet manufacturer's specifications for washability and/or scrubability. If the paint product fails to meet the standards of this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Wall Coverings.

  (1) A wall covering shall be properly secured to the wall surface and shall not peel or bubble. If a wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Pattern repeats in wall coverings shall match. Wall coverings shall be installed square to the most visible wall. Pattern repeats shall not vary in an amount equal to or exceeding 1/4 of an inch in any six-foot run. If the wall covering fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A wall covering seam shall not separate or gap. If the wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Lumps or ridges in a wall covering shall not be detectable from a distance of six feet or more in normal light. If the appearance of the wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) Wall coverings shall not be discolored, stained or spotted due to construction activities. If a wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (6) Wall coverings shall not be scratched, gouged, cut or torn due to construction activities. If a wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) Wall coverings shall perform as represented by the manufacturer to meet manufacturer's specifications for washability and/or scrubability. If a wall covering fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.22

Performance Standards for Plumbing

 


(a) Performance Standards for Plumbing Accessories.

  (1) A fixture surface shall not have a chip, crack, dent or scratch due to construction activities. If a fixture fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) A fixture shall not have tarnish, blemishes or stains unless installed as a specialty feature.

    (A) If a fixture fails to meet the standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) Fixture finishes that are tarnished, blemished or stained due to high iron, manganese or other mineral content in water are excluded from this standard.

  (3) A fixture or fixture fastener shall not corrode.

    (A) If a fixture or fixture fastener fails to meet the standards of paragraph (3) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) A builder is not responsible for corrosion caused by factors beyond the manufacturer's or the builder's control, including the homeowner's use of corrosive chemicals or cleaners or corrosion caused by water content.

  (4) A decorative gas appliance shall be installed in accordance with manufacturer's specifications and when so installed shall function in accordance with manufacturer's representations. If a decorative gas appliance fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) Fixtures shall be secure and not loose.

    (A) If a fixture fails to meet the standard stated in paragraph (5) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall not exert excessive force on a fixture.

  (6) A fixture stopper shall operate properly and shall retain water in accordance with the manufacturer's specifications. If a fixture stopper fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (7) The toilet equipment shall not allow water to run continuously.

    (A) If the toilet equipment fails to meet the standard stated in paragraph (7) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) If toilet equipment allows water to run continuously, the homeowner shall shut off the water supply or take such action as is necessary to avoid damage to the home.

  (8) A toilet shall be installed and perform in accordance with the manufacturer's specifications.

    (A) If a toilet fails to meet the standard stated in paragraph (8) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) In the event of water spillage, the homeowner shall shut off the water supply and take such action as is necessary to avoid damage to the home.

  (9) A tub or shower pan shall not crack. If a tub or shower pan fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (10) A tub or shower pan shall not squeak excessively. If a tub or shower pan fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (11) A water heater shall be installed and secured according to the manufacturer's specifications and the Code. If a water heater fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (12) A waste disposal unit shall be installed and operate according to the manufacturer's specifications. If a waste disposal unit fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (13) A faucet or fixture shall not drip or leak. This standard does not include drips or leaks due to debris or minerals from the water source, unless it is due to construction activities. If a faucet or fixture fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (14) A sump pump shall be installed in accordance with the manufacturer's specifications and shall operate properly when so installed. If a sump pump fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Pipes and Vents.

  (1) A sewer gas odor originating from the plumbing system shall not be detectable inside the home under conditions of normal residential use.

    (A) If a sewer gas odor is detected inside the home under conditions of normal residential use, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall keep plumbing traps filled with water.

  (2) A vent stack shall be free from blockage and shall allow odor to exit the home. If a vent stack fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A water pipe shall not make excessive noise such as banging or hammering repeatedly.

    (A) If a water pipe fails to meet the standard stated in paragraph (3) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) A water pipe subject to expansion or contraction of the pipe as warm or cool water flows through the pipe may cause a "ticking" sound temporarily. The standard stated in paragraph (3) of this subsection does not require a builder to remove all noise attributable to water flow and pipe expansion.

RULE §304.23

Performance Standards for Heating, Cooling and Ventilation

 


(a) Performance Standards for Heating and Cooling.

  (1) A condensation line shall not be obstructed due to construction activities.

    (A) If a condensation line fails to meet the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall periodically check for the free flow of condensate (water) from the line and clear the line when necessary.

  (2) A drip pan and drain line shall be installed under a horizontal air handler as per the Code.

    (A) If a drip pan and drain line fails to meet the standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall periodically check for the free flow of condensate (water) from the line and clear the line when necessary.

  (3) Insulation shall completely encase the refrigerant line according to Code.

    (A) If the refrigerant line insulation fails to meet the standard stated in paragraph (3) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall ensure that insulation on the refrigerant line is not damaged or cut due to home maintenance or landscape work.

  (4) An exterior compressor unit shall be installed on a stable pad that supports the unit and is no more than one inch out of level. The bottom of the exterior compressor unit support shall not be below ground level.

    (A) If an exterior compressor unit pad or support fails to meet the standards stated in paragraph (4) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall ensure that settlement of the exterior compressor unit pad does not occur due to home maintenance, landscape work or excessive water from irrigation.

(b) Performance Standards for Venting.

  (1) An appliance shall be vented according to the manufacturer's specifications. If an appliance is not vented in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) Back draft dampers shall be installed and function according to the manufacturer's specifications. If back draft dampers fail to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) Performance Standards for Ductwork. Ductwork shall not make excessive noise.

  (1) If the ductwork fails to meet the standard stated in of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The flow of air, including its velocity, or the expansion of ductwork from heating and cooling may cause "ticking" or "crackling" sounds.

  (3) The homeowner shall not place any object on the ductwork.

RULE §304.24

Performance Standards for Electrical Systems and Fixtures

 


(a) Excessive air infiltration shall not occur around electrical system components or fixtures. If electrical system components or fixtures fail to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(b) A fixture or trim plate shall not be chipped, cracked, dented or scratched due to construction activities. If a fixture or trim plate fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A fixture or trim plate finish shall not be tarnished, blemished or stained due to construction activities. If a fixture or trim fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(d) A fixture, electrical box or trim plate shall be installed in accordance with the Code and shall be plumb and level. If a fixture, electrical box or trim plate fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(e) Fixtures, such as lights, fans and appliances shall operate properly when installed in accordance with the manufacturer's specifications. The builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(f) A smoke detector shall operate according to the manufacturer's specifications and shall be installed in accordance with the Code. If a smoke detector fails to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(g) An exhaust fan shall operate within the manufacturer's specified noise level. If an exhaust fan fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.25

Performance Standards for Interior Trim

 


(a) Performance Standards for Trim.

  (1) An interior trim joint separation shall not equal or exceed 1/8 of an inch in width and all joints shall be caulked or puttied. If an interior trim joint fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The interior trim shall not have surface damage, such as scratches, chips, dents, gouges, splits, cracks, warping or cupping that is visible from a distance of six feet or more in normal light due to construction activities. If the interior trim fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A hammer mark on trim shall not be visible from a distance of six feet or more when viewed in normal light. If the interior trim fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) A nail or nail hole in interior trim shall not be visible from a distance of six feet or more when viewed in normal light. If the interior trim fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Shelving. Shelving, rods and end supports shall be installed in accordance with the measurements stated in this subsection. The length of a closet rod shall not be shorter than the actual distance between the end supports in an amount equal to or exceeding 1/4 of an inch and shall be supported by stud-mounted brackets no more than four feet apart. The length of a shelf shall not be shorter than the actual distance between the supporting walls by an amount equal to or exceeding 1/4 of an inch and shall be supported by stud-mounted brackets no more than four feet apart. End supports shall be securely mounted. If the closet rods, shelving or end supports fail to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.26

Performance Standards for Mirrors, Interior Glass and Shower Doors

 


(a) A mirror, interior glass or shower door shall not be loose and shall be securely mounted or attached to the supporting surface. Fixtures, such as towel bars or door handles, shall be securely mounted. If a mirror, interior glass, shower door, fixture or component fails to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(b) A mirror, interior glass or shower door shall not be damaged due to construction activities. If a mirror, interior glass or shower door fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A shower door shall not leak. If a shower door fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Imperfections in a mirror or shower door shall not be visible from a distance of two feet or more when viewed in normal light. If a mirror or shower door fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(e) When opening and closing, a shower door shall operate easily and smoothly without requiring excessive pressure. If a shower door fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.27

Performance Standards for Hardware and Ironwork

 


(a) Performance Standards for Hardware.

  (1) Hardware finishes shall not be tarnished, blemished, corroded or stained due to construction activities, unless the finish is installed as a specialty feature.

    (A) If the hardware finish fails to meet the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The builder is not responsible for tarnished, blemished, or stained hardware finishes that have been damaged by factors that are beyond the manufacturer's or the builder's control such as the homeowner's use of abrasive pads or cleaners, harsh chemicals, alcohol, organic solvents or deterioration caused by exposure to outdoor elements such as salt air or humidity.

  (2) Hardware shall function properly, without catching binding or requiring excessive force to operate. If hardware fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Hardware shall not be scratched, chipped, cracked or dented due to construction activities. If hardware fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Hardware shall be installed securely and shall not be loose.

    (A) If hardware fails to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) The homeowner shall not exert excessive force on hardware.

(b) Performance Standards for Interior Ironwork.

  (1) Interior ironwork shall not rust.

  (2) If interior ironwork fails to meet the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) The builder is not responsible for ironwork finishes that rust due to factors that are beyond the manufacturer's or the builder's control such as the homeowner's use of abrasive pads or cleaners, harsh chemicals, alcohol, organic solvents or deterioration caused by exposure to humidity.

RULE §304.28

Performance Standards for Countertops and Backsplashes

 


(a) Performance Standards for Countertops and Backsplashes Generally.

  (1) A countertop or backsplash shall be secured to substrate in accordance with manufacturer's specifications. If countertop or backsplash materials are not secured to the substrate in accordance with the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) For non-laminate countertops and backsplashes, the joints between countertop surfaces, between the countertop surface and the backsplash or side-splash and between adjoining backsplash panels may be visible, but shall not separate. If joints between non-laminate surfaces fail to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) Countertops shall be level to within 1/4 of an inch in any six-foot measurement. If a countertop surface fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) A countertop surface or edge shall not be damaged, broken, chipped or cracked due to construction activities. If a countertop surface or edge fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (5) A countertop shall not bow or warp in an amount equal to or exceeding 1/16 of an inch per lineal foot. If a countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(b) Performance Standards for Laminate Countertops and Backsplashes.

  (1) Laminate countertops and backsplashes shall not delaminate and shall remain securely attached to the substrate. Delamination is the separation of the finish surface veneer from the substrate material. If a countertop fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) A seam in a laminate countertop or backsplash may be visible but shall not be separated or displaced. If a laminate countertop or backsplash fails to meet the standard stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

  (3) A surface imperfection in a laminate countertop or a backsplash shall not be visible from a distance of three feet or more when viewed in normal light due to construction activities. If a laminate surface fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.29

Performance Standards for Fireplaces

 


(a) A refractory panel shall not crack or separate.

  (1) If the fireplace refractory panel fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The homeowner shall not use synthetic logs or other materials if not approved by the manufacturer.

(b) A fireplace door shall operate properly. Fireplace doors shall meet evenly and shall not be out of alignment from one another in an amount equal to or exceeding 1/8 of an inch in any direction. If a fireplace door fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A fireplace shall not have a gas leak. If a fireplace has a gas leak, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

(d) Gas logs shall be positioned in accordance with the manufacturer's specifications.

  (1) If a gas log fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The homeowner shall not incorrectly reposition or relocate the logs after the original placement. The homeowner shall not place the logs in a manner that does not allow the flame to flow through the logs according to the manufacturer's specifications.

(e) A crack in masonry hearth or facing shall not be equal to or exceed 1/4 of an inch in width. If the masonry hearth or facing of the fireplace fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(f) A fireplace or chimney shall draw properly. If a fireplace or chimney fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(g) A firebox shall not have excessive water infiltration under normal weather conditions. If a firebox fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(h) A fireplace fan shall not exceed the noise level established by the manufacturer's specifications. If a fireplace fan fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.30

Performance Standards for Irrigation Systems

 


(a) An irrigation system shall not leak, break or clog due to construction activities. If an irrigation system fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(b) An irrigation system shall be installed such that sprinkler coverage shall be complete and water shall not spray an unintended area due to construction activities. If an irrigation system fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) The irrigation system control shall operate in accordance with manufacturer's specifications.

  (1) If an irrigation system fails to operate in accordance with manufacturer's specifications, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

  (2) The builder shall provide the homeowner with instructions on the operation of the irrigation system at closing.

RULE §304.31

Performance Standards for Fencing

 


(a) A fence shall not fall over and shall not lean in excess of two inches out of plumb due to construction activities. If the fencing fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(b) A wood fence board shall not be broken due to construction activities. Wood fence board shall not become detached from the fence due to construction activities of the builder. If the fencing fails to meet the standards stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(c) A masonry unit or mortar in a fence shall not be broken or loose. A crack in a masonry unit shall not occur. A crack in the mortar shall not equal or exceed 1/8 of an inch in width. If a masonry unit or mortar in a fence fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

(d) A masonry wall shall have adequate weep holes in the lowest course as required by the Code to allow seepage to pass through the wall. If a masonry retaining wall fails to meet the standards of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.32

Performance Standards for Yard Grading

 


(a) Yards shall have grades and swales that provide for proper drainage away from the home in accordance with the Code or other governmental regulations.

  (1) If the grades or swales fail to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

  (2) The homeowner shall maintain the drainage pattern and protect the grading contours from erosion, blockage, over-saturation or any other changes.

(b) Settling or sinking of soil shall not interfere with the drainage patterns of the lot or have a vertical depth of six inches or more. If the soil fails to meet the standard stated in this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

RULE §304.33

Performance Standards for Pest Control

 


Eave returns, truss blocks, attic vents and roof vent openings shall not allow rodents, birds, and other similar pests into home or attic space. If an eave return, truss block, attic vent or roof vent opening that allows rodents, birds, and other similar pests into home or attic space, the builder shall take such action as is necessary to bring the variance within the standard state in this section.

 

RULE §304.50

Performance Standards for Electrical Delivery Systems

 


(a) Performance Standards for Electrical Wiring.

  (1) Electrical wiring installed inside the home shall be installed in accordance with the Code and any other applicable electrical standards and shall function properly from the point of demarcation, as determined by the respective utility.

    (A) If electrical wiring inside the home is not functioning properly or is not installed in accordance with the Code and any other applicable electrical standards, the builder shall take such action as is necessary to bring the wiring to the standard of performance required in paragraph (1) of this subsection.

    (B) The builder shall not be responsible for utility improvements from the meter/demarcation point to the utility poles or the transformer.

  (2) Electrical wiring shall be capable of carrying the designated load as set forth in the Code.

    (A) If the electrical wiring fails to carry design load, the builder shall take such action as is necessary to bring the variance within the standard set forth in paragraph (2) of this subsection.

    (B) All electrical equipment shall be used for the purposes and/or capacities for which it was designed and in accordance with manufacturer's specifications.

(b) Performance Standards for the Electrical Panel, Breakers and Fuses.

  (1) The electrical panel and breakers shall have sufficient capacity to provide electrical service to the home during normal residential usage.

    (A) If the electrical panel or breakers do not have sufficient capacity to provide electrical service to the home during normal residential usage, the builder shall take such action as is necessary to bring the variance within the standard set forth in paragraph (1) of this subsection.

    (B) The builder is not responsible for electrical service interruptions caused by external conditions such as power surges, circuit overloads and electrical shorts.

  (2) The electrical panel and breakers shall have sufficient capacity to provide electrical service to the home during normal residential usage such that a circuit breaker shall not trip and fuses shall not blow repeatedly under normal residential electric usage.

    (A) If a circuit breaker repeatedly trips or fuses repeatedly blow under normal residential electric usage, the builder shall take such action as is necessary to bring the variance within the standard set forth in paragraph (2) of this subsection.

    (B) The builder is not responsible for circuit breaker trips or blown fuses that have functioned as designed to protect the home from external conditions such as power surges, circuit overloads and shorts.

(c) Performance Standards for Electric Outlets with Ground Fault Interrupters.

  (1) Electrical outlets with ground fault interrupters shall be installed and operate in accordance with the Code and manufacturer's specifications. If ground fault interrupters trip repeatedly under normal residential usage, the builder shall take such action as is necessary to ensure that the electrical outlets with ground fault interrupters are installed in accordance with the Code and manufacturer's instructions and specifications and that they operate properly during normal residential electrical usage.

  (2) The homeowner shall not plug appliances that require constant electrical flow, such as refrigerators and freezers, into an outlet with a ground fault interrupter.

(d) Performance Standards for Fixtures, Outlets, Doorbells and Switches.

  (1) An outlet, doorbell or switch shall be installed in accordance with the manufacturer's specifications and the Code and shall operate properly when installed in accordance with the manufacturer's specifications and the Code. If an outlet, doorbell or switch is not installed in accordance with the manufacturer's specifications and the Code or does not operate properly when so installed, the builder shall take such action as is necessary to bring the variance within the standard stated in this subsection.

  (2) A fixture, electrical box or trim plate shall be installed in accordance with the Code and manufacturer's specifications and shall be properly secured to the supporting surface. If a fixture, electrical box or trim plate is not installed in accordance with the Code and manufacturer's specifications or is not properly secured to the supporting surface, builder shall take such action as is necessary to bring the variance within the standard state in this subsection.

  (3) A light shall not dim, flicker or burn out repeatedly under normal circumstances. A lighting circuit shall meet the Code. If a light or a lighting circuit fails to meet the standards stated in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(e) Performance Standards for Wiring or Outlets for Cable Television, Telephone, Ethernet or Other Services.

  (1) Wiring or outlets for cable television, telephone, ethernet or other services shall be installed in accordance with the Code and any applicable manufacturer's specifications.

    (A) If wiring or outlets for cable television, telephone, ethernet or other services are not installed in accordance with the Code or any applicable manufacturer's specifications, the builder shall take such action as is necessary to bring the variance within the standard set forth in paragraph (1) of this subsection.

    (B) A builder is not responsible for the failure of wiring or other utility service connectors or conduits that begin before the point at which the service enters the home.

  (2) Wiring or outlets for cable television, telephone, ethernet or other services inside the home or on the home side of the meter/demarcation point shall function properly when installed in accordance with the performance standard in paragraph (1) of this subsection.

    (A) If wiring or outlets for cable television, telephone, ethernet or other services are not functioning, the builder shall take such action as is necessary to bring the variance within the standard set forth in paragraph (2) of this subsection.

    (B) A builder is not responsible for the failure of wiring or other utility service connectors or conduits that begin before the point at which the service enters the home.

RULE §304.51

Performance Standards for Plumbing Delivery Systems

 


(a) Performance Standards for Pipes including Water and Gas Pipes, Sewer and Drain Lines, Fittings and Valves but not including pipes included in a Landscape Irrigation System.

  (1) Pipes shall be installed and insulated in accordance with the Code and manufacturer's specifications.

    (A) If a water pipe bursts, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (1) of this subsection.

    (B) The homeowner is responsible for insulating and protecting exterior pipes and hose bibs from freezing weather and for maintaining a reasonable temperature in the home during periods of extremely cold weather. The homeowner is responsible for maintaining a reasonable internal temperature in a home regardless of whether the home is occupied or unoccupied and for periodically checking to ensure that a reasonable internal temperature is maintained.

  (2) A water pipe shall not leak.

    (A) If a water pipe is leaking, the builder shall take such action as is necessary to bring the variance within the performance standard stated in paragraph (2) of this subsection.

    (B) The homeowner shall shut off water supply immediately if such is required to prevent further damage to the home.

  (3) A gas pipe shall not leak, including natural gas, propane or butane gas.

    (A) If a gas pipe is leaking, a builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (3) of this subsection.

    (B) If a gas pipe is leaking, the homeowner shall shut off the source of the gas if the homeowner can do so safely.

  (4) Water pressure shall not exceed 80 pounds per square inch in any part of the water supply system located inside the home. Minimum static pressure at the building entrance for either public or private water service shall be 40 pounds per square inch in any part of the water supply system.

    (A) This standard assumes the public or community water supply reaches the home side of the meter at 40 pounds per square inch. The builder is not responsible for water pressure variations originating from the water supply source.

    (B) If the water pressure is excessively high, the builder shall take such action as is necessary to bring the variance within the standard stated in paragraph (4) of this subsection.

  (5) A sewer, drain, or waste pipe shall not become clogged or stopped up due to construction activities.

    (A) The builder shall take such action as is necessary to unclog a sewer, drain or waste pipe that is clogged or stopped up due to construction activities.

    (B) The homeowner shall shut off water supply immediately if such is required to prevent damage to the home.

(b) Performance Standards for Individual Wastewater Treatment Systems. A wastewater treatment system should be capable of properly handling normal flow of household effluent in accordance with the Texas Commission on Environmental Quality requirements.

  (1) The builder shall take such action as is necessary for the wastewater treatment system to perform within the standard stated in this subsection.

  (2) The builder is not responsible for:

    (A) system malfunctions or damage due to the addition of a fixture, equipment, appliance or other source of waste or water into the septic system by a person other than the builder or a person working at the builder's direction; or

    (B) malfunctions or limitations in the operation of the system attributed to a design restriction imposed by state, county or local governing agencies; or

    (C) malfunctions caused by freezing, soil saturation, soil conditions, changes in ground water table or any other acts of nature.

SUBCHAPTER C

PERFORMANCE STANDARDS FOR PLUMBING, ELECTRICAL, HEATING AND AIR-CONDITIONING DELIVERY SYSTEMS SUBJECT TO A MINIMUM WARRANTY PERIOD OF TWO YEARS

RULE §304.52

Performance Standards for Heating, Air Conditioning and Ventilation Delivery Systems

 


(a) A refrigerant line shall not leak.

  (1) If a refrigerant line leaks, the builder shall take such action as is necessary to bring the variance within the standard stated in subsection (a) of this section.

  (2) Condensation on a refrigerant line is not a leak.

(b) Performance Standards for Heating and Cooling Functions.

  (1) A heating system shall produce an inside temperature of at least 68-degrees Fahrenheit as measured two feet from the outside wall of a room at a height of three feet above the floor under local outdoor winter design conditions as specified in the Code.

    (A) If a heating system fails to perform to the standard stated in paragraph (1) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) Temperatures may vary up to 4-degrees Fahrenheit between rooms but no less than the standard set forth above in paragraph (1) of this subsection. The homeowner's changes made to the size or configuration of the home, the heating system or the ductwork shall negate the builder's responsibility to take measures to meet this performance standard.

  (2) An air-conditioner system shall produce an inside temperature of at most 78-degrees Fahrenheit as measured in the center of a room at height of five feet above the floor, under local outdoor summer design conditions as specified in the Code.

    (A) If the air-conditioner system fails to perform to the standard stated in paragraph (2) of this subsection, the builder shall take such action as is necessary to bring the variance within the standard.

    (B) This standard does not apply to evaporative or other alternative cooling systems or if the homeowner makes changes to the size or configuration of the home, the air-conditioning system or the ductwork. Internal temperatures may vary up to 4-degrees Fahrenheit between rooms but no more than the standard set forth above in paragraph (2) of this subsection.

  (3) A thermostat reading shall not differ by more than 4-degrees Fahrenheit from the actual room temperature taken at a height of five feet above the floor in the center of the room where the thermostat is located. The stated performance standard is related to the accuracy of the thermostat and not to the performance standard of the room temperature. If the thermostat reading differs more than 4-degrees Fahrenheit from the actual room temperature taken at a height of five feet above the floor in the center of the room where the thermostat is located, the builder shall take such action as is necessary to bring the variance within the standard.

  (4) Heating and cooling equipment shall be installed and secured according to the manufacturer's instructions and specification and shall not move excessively. If the heating or cooling equipment is not installed and secured in accordance with manufacturer's instructions and specifications or moves excessively, the builder shall take such action as is necessary to properly install and secure the equipment.

(c) Performance Standards for Vents, Grills or Registers.

  (1) A vent, grill or register shall operate easily and smoothly when applying normal operating pressure. If a vent, grill or register does not operate easily and smoothly when applying normal pressure when adjusting, the builder shall repair the vent, grill or register so that it operates with ease of use when applying normal operating pressure.

  (2) A vent, grill or register shall be installed in accordance with the Code and manufacturer's instructions and specifications and shall be secured to the underlying surface. If a vent, grill or register is not installed and secured in accordance with the performance standard in this paragraph, the builder shall take such action as is necessary to bring the variance within the standard.

(d) Performance Standards for Ductwork.

  (1) Ductwork shall be insulated in unconditioned areas according to Code. If ductwork is not insulated in unconditioned areas in accordance with the Code, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (2) Ductwork shall be secured according to the manufacturer's instructions and specifications and it shall not move excessively. If the ductwork is not secured according to the manufacturer's instructions and specifications or moves excessively, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

  (3) Ductwork shall be sealed and shall not separate or leak in excess of the standards set by the Code. If the ductwork is not sealed, is separated or leaks in excess of the standards set by the Code, the builder shall take such action as is necessary to bring the variance within the standard stated in this paragraph.

SUBCHAPTER D

PERFORMANCE STANDARDS FOR FOUNDATIONS AND MAJOR STRUCTURAL COMPONENTS OF A HOME SUBJECT TO A MINIMUM WARRANTY PERIOD OF TEN YEARS

RULE §304.100

Performance Standards for Major Structural Components

 


(a) Performance Standards for Slab Foundations.

  (1) Slab foundations should not move differentially after they are constructed, such that a tilt or deflection in the slab in excess of the standards defined below arises from post-construction movement. The protocol and standards for evaluating slab foundations shall follow the "Guidelines for the Evaluation and Repair of Residential Foundations" as published by the Texas Section of the American Society of Civil Engineers (2002), hereinafter referred to as the "ASCE Guidelines" with the following modifications:

    (A) Overall deflection from the original construction elevations shall be no greater than the overall length over which the deflection occurs divided by 360 (L/360) and must not have more than one associated symptom of distress, as described in Section 5 of the ASCE Guidelines, that results in actual observable physical damage to the home.

    (B) The slab shall not deflect after construction in a tilting mode in excess of one percent from the original construction elevations resulting in actual observable physical damage to the components of the home.

  (2) If measurements and associated symptoms of distress show that a slab foundation does not meet the deflection or tilt standards stated in paragraph (1) of this subsection, a third-party inspector's recommendation shall be based on the appropriate remedial measures as described in Section 7 of the ASCE Guidelines.

(b) Performance Standards for Major Structural Components of a Home other than Slab Foundations.

  (1) Floor over pier and beam foundations.

    (A) A floor over pier and beam foundation shall not deflect more than L/360 from its original construction elevations and have that movement create actual observable physical damage to the components of the home identifiable in Section 5.3 of the ASCE Guidelines.

    (B) If a floor over pier and beam foundation deflects more than L/360 from its original construction elevation and the movement has created actual observable physical damage to the components of a home identifiable in Section 5.3 of the ASCE Guidelines, a third-party inspector's recommendation shall be based on applicable remedial measures as described in Section 7 of the ASCE Guidelines.

  (2) Structural components.

    (A) A defined structural component shall not crack, bow, become distorted or deteriorate, such that it compromises the structural integrity of a home or the performance of a structural system of the home resulting in actual observable physical damage to a component of the home.

    (B) If a structural component of a home cracks, bows, is distorted or deteriorates such that it results in actual observable physical damage to a component of the home, the builder shall take such action as is necessary to repair, reinforce or replace such structural component to restore the structural integrity of the home or the performance of the affected structural system.

  (3) Deflected structural components.

    (A) A structural component shall not deflect more than the ratios allowed by the Code.

    (B) If a structural component of the home is deflected more than the ratios allowed by the Code, the builder shall to repair, reinforce or replace such structural component to restore the structural integrity of the home or the performance of the affected structural system.

  (4) Damaged structural components.

    (A) A structural component shall not be so damaged that it compromises the structural integrity or performance of the affected structural system.

    (B) If a structural component is so damaged that it compromises the structural integrity or performance of a structural system of the home, the builder shall take such action as is necessary to repair, reinforce or replace such structural component to restore the structural integrity of the home or the performance of the affected structural system.

  (5) Separated structural components.

    (A) A structural component shall not separate from a supporting member more than 3/4 of an inch or such that it compromises the structural integrity or performance of the system.

    (B) If a structural component is separated from a supporting member more than 3/4 of an inch or separated such that it compromises the structural integrity or performance of a structural system of the home, the builder shall take such action as necessary to repair, reinforce or replace such structural component to re-establish the connection between the structural component and the supporting member, to restore the structural integrity of the home and the performance of the affected structural system.

  (6) Non-performing structural components.

    (A) A structural component shall function as required by the Code.

    (B) If a structural component does not function as required by the Code, the builder shall take such action as is necessary to bring the variance within the standard stated in subparagraph (A) of this paragraph.

 

Chapter 304. Limited Statutory Warranty and Building and Performance Standards (effective June 1, 2005)

Chapter 304. Subchapter B

Chapter 304. Subchapter C

Chapter 304. Subchapter D

If you have any questions, or are interested in any other services, please contact us so we may discuss your specific needs.


ADAIR INSPECTION TREC#4563 1733 Goliad Dr Garland, TX 75042-4238
Phone: (972) 487-5634 Cell: (214) 328-8331

Radon Information | Staff & Associates | Testimonials | Contact Us | Lead in the home | Inspection Prices | Vendor List | My Favorite Links | RepairCostLifeExpectancyAge | Free Home Care Guide | Satisfaction Survey | Tech Tips | Affiliate Links | Fire Prevention & Safety | Ed. & Cetification | Sample Reports | Pool-Spa Safety | Electrical Safety | Environmental Research | EIFS - Stucco - Siding | Service Area | Phase Inspection | CRAP Photos | Infrared Thermography | I'm Licensed & Qualified! | Carbon Monoxide CO | Client Login | Home Buyer Checklist | Tell a Friend | Environmental Issues | Real Estate News | FAQ | Press Release | Glossary of Terms | Home | Our Service Area | Most Common Defects | Services | Inspection vs. Appraisal | Inspector vs. Engineer | New Home Inspection | Pre-purchase Inspection | Septic Inspection | What's an Inspection SOP | Listing Inspection | Order Inspections | Winterize your Home | Mold in the home | ReportReadingGlossary | How to prepare | Residential investment | NACHI Membership | NACHI Code of Ethics | How to Hire an Inspector | HVAC Issues | Roofing Issues | Hidden Water Damage | Plumbing Issues | Termites and Other Pests | Asbestos Information

Copyright © 2007 ADAIR INSPECTION TREC#4563
Portions Copyright © 2007 a la mode, inc.
Another XSite by a la mode, inc. | Admin LoginTerms of UseSite Map